Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611

Continuous turbidity monitoring.
See the first sign of
trouble in the water.

Real-time turbidity and suspended solids monitoring in NTU. A turbidity spike is often the first indicator of pipe disturbance, filter breakthrough or contamination ingress. Catch it the moment it starts.

UK-based engineering team Retrofit-friendly deployment Audit-ready records
Site Monitoring Live
pH
7.24
Potential of Hydrogen
Turbidity
0.42
NTU
Free Cl₂
0.08
mg/L
Dissolved O₂
8.71
mg/L
Conductivity
342
µS/cm

Example readings for illustration purposes

What you can’t see
is already costing you.

Reactive call-outs

Issues are flagged after damage is done, not before it starts. Every delayed alert is a cost you didn’t have to carry.

Fragmented compliance

Manual records, missed checks, and audit gaps across sites. When an inspector asks for evidence, the scramble begins.

Hidden drift

pH, chlorine, or turbidity can shift for days or weeks before anyone notices. Without real-time monitoring, you’re always reacting.

Continuous monitoring.
Instant alerts. Full audit trail.

Three connected layers that turn raw sensor data into actionable intelligence, automatically.

1. Monitor

Connected sensors stream real-time data across all parameters, 24 hours a day. Cellular and LoRaWAN telemetry with encrypted payloads.

2. Alert

Threshold breaches trigger instant SMS, email, or app notifications. Escalation rules and role-based routing ensure the right person acts.

3. Respond

Cloud dashboards give your team the data, trendlines, and records they need, instantly. Every reading logged, every action auditable.

Every parameter.
One connected system.

From standard chemistry to full-spectrum UV-Vis sensing, AQUAIOT covers every dimension of water quality your operation demands.

SPS-pH Water Quality Sensor
pH
SPS-pH Sensor

Continuous acidity and alkalinity monitoring. Detect corrosion risk, Legionella-risk conditions, and treatment performance drift.

Optimal drinking water pH: 6.5–9.5. Drift outside this range signals treatment failure or infrastructure issues.
SPS-T-SC1 Turbidity Sensor
Turbidity & Suspended Solids
SPS-T-SC1 Sensor

Detect particulate contamination, filter breakthrough, and process upsets in real time.

Turbidity spikes are often the first indicator of pipe disturbance, contamination ingress, or treatment failure.
SPS-CI Free Chlorine Sensor
Free Chlorine
SPS-CI-C Sensor

Continuous disinfection residual monitoring. Ensure treatment efficacy without manual sampling delays.

Chlorine residual below 0.1 mg/L creates microbial risk. Continuous monitoring catches drops before they become incidents.
SPS-DO Dissolved Oxygen Sensor
Dissolved Oxygen
SPS-DO Sensor

Monitor oxygen levels critical for biological process control, aeration efficiency, and environmental compliance.

Low DO in wastewater systems indicates biological stress; in distribution it can indicate contamination ingress.
SPS-EC Conductivity Sensor
Conductivity
SPS-EC Sensor

Track dissolved mineral content and detect contamination events, cross-connections, or treatment changes in real time.

Sudden conductivity changes are a rapid indicator of intrusion, saline ingress, or chemical contamination.
SPS-F Full Spectrum Water Quality Sensor
Full-Spectrum UV-Vis
SPS-F SpecSens Sensor

Specsens UV-Vis sensing at the edge. Detect organic load, humic substances, and complex contamination signatures beyond single-parameter sensors.

Full-spectrum sensing captures richer water quality signatures, ideal for source water characterisation and treatment optimisation.
SPS-Color-C Colour Sensor
Colour
SPS-Color-C Sensor

Detect apparent and true colour changes that may indicate natural organic matter, iron, manganese, or treatment by-products.

Colour is a key aesthetic and compliance parameter, continuous monitoring prevents visible discolouration events reaching consumers.
SPS-ORP Water Quality Sensor
ORP
SPS-ORP Sensor

Oxidation-reduction potential monitoring for disinfection effectiveness, redox conditions, and process control in treatment and distribution.

ORP is a direct measure of disinfection power, falling ORP values indicate that treatment residual is being depleted.

Want the full technical specifications for every sensor?

Download Datasheet

Turbidity is the earliest warning you get. Do not miss it.

Turbidity, the cloudiness caused by suspended particles, is one of the most sensitive early indicators in water. A sudden rise frequently precedes a recognised problem, signalling pipe disturbance, filter breakthrough at a treatment works, a process upset, or contamination entering the system. By the time turbidity is visible to the eye, the event is already well advanced.

AQUAIOT monitors turbidity and suspended solids continuously with the SPS-T-SC1 sensor, including ultra-low turbidity variants for treated water. Real-time readings in NTU stream to the cloud, and threshold alerts fire the instant clarity degrades, giving operators the window to isolate, investigate and respond before a spike becomes an incident or a failed sample.

  • Real-time turbidity and suspended solids in NTU
  • Detects filter breakthrough, pipe disturbance and process upsets
  • Ultra-low turbidity sensing available for treated water
  • Threshold alerts before a spike reaches consumers or a sample point
At a glance

Turbidity monitoring specifics

MeasuresTurbidity & suspended solids
UnitNTU
FlagsFilter breakthrough, ingress
HardwareSPS-T-SC1 sensor
Speak to an Expert

Integrated monitoring systems,
not just sensors.

AQUAIOT combines connected sensors, cloud visibility, and engineering support into end-to-end deployments built around your infrastructure.

iSPA-T Multi-parameter Water Quality Monitoring System
iSPA-T
Multi-parameter Online Monitoring System

Integrated online monitoring system combining multiple sensing modalities, cloud telemetry, and dashboard connectivity in a single deployable unit.

View product
iSPS-X Multi-parameter Water Quality Instrument
iSPS-X
Multi-parameter Measurement Instrument

Versatile multi-parameter instrument supporting simultaneous measurement across key water quality indicators with flexible sensor configuration.

View product
SPA Chlorine Free/Total Chlorine Analyzer
SPA Chlorine Analyzer
Free & Total Chlorine Water Quality Analyser

Dedicated chlorine analysis with continuous free and total chlorine measurement, built for treatment, distribution, and compliance-relevant applications.

View product

From sensor edge to
operations dashboard

Every AQUAIOT deployment is built for the operational realities of UK water and estates teams, retrofit-friendly, open to your existing systems, and supported by engineers who understand what you’re monitoring and why.

  • Cellular + LoRaWAN telemetry with encrypted payloads
  • Over-the-air configuration & firmware management
  • RS485/Modbus · APIs for SCADA, AIMS/CAFM & analytics
  • Role-based dashboards, trendlines, alarms & exports
  • Exportable, audit-ready compliance records

Every reading. Every alert.
Every record. In one place.

Your monitoring data consolidated into a single cloud platform, built for operations, not just engineers.

AQUAIOT DASHBOARD · SITE OVERVIEW All Systems Normal
pH Current
7.24
↑ +0.02 vs 1hr ago
Free Cl₂
0.08
⚠ Low threshold
Turbidity
0.42
NTU · Normal
Free Chlorine — 24hr trend (mg/L)
Free Cl₂ approaching low threshold — Site A, Zone 3 14 mins ago
Daily compliance report generated — exported to CAFM 2 hrs ago
pH normalised after overnight treatment — all parameters within range 6 hrs ago
Real-time dashboards

Role-based cloud views with trendlines, threshold alarms, and multi-site visibility. Export data directly to your analytics stack.

Compliance records

Audit-ready trails generated automatically. Exportable logs and API integration with BMS, CAFM, and compliance platforms.

Intelligent alerts

SMS, email, and app notifications with escalation rules and role-based routing. Your team is notified before issues escalate.

Remote configuration

Over-the-air firmware updates and remote sensor configuration. Reduce site visits and keep systems current without disruption.

The engineering partner,
not just the hardware supplier.

AQUAIOT brings years of engineering experience alongside cutting-edge technology, so your deployment doesn’t end at the sensor.

End-to-end delivery

Site survey, installation, commissioning, dashboard setup, training, and post-installation support. We see it through.

Retrofit-friendly

Clamp-on ultrasonic flow meters and non-invasive sensors. No pipework cutting, no service shutdown, no disruption to live systems.

Open & interoperable

RS485/Modbus, APIs, SCADA, AIMS/CAFM integration. Built to connect, not to lock you in to a closed ecosystem.

UK engineering support

Hampshire-based team offering on-site and remote technical support. Real engineers, available when it matters.

Built for operational teams
who need to know.

Water quality monitoring isn’t one-size-fits-all. AQUAIOT deploys across the full range of UK water and estates operations.

Water Utilities Distribution monitoring, treatment compliance, and network resilience
Councils & Local Authorities Public infrastructure monitoring, drainage, and environmental oversight
NHS & Public-Sector Estates Legionella compliance, Legionella-risk monitoring, and audit-ready records
Housing Providers Large-scale Legionella and water quality monitoring across housing stock
Facilities & Asset Managers Estate-wide visibility with minimal manual intervention
Commercial Estates Water quality assurance, compliance support, and operational reporting

Turbidity monitoring questions

What does a turbidity spike indicate?
A sudden rise in turbidity often signals pipe disturbance, filter breakthrough at a treatment works, a process upset, or contamination ingress. It is frequently the first measurable sign of a developing problem, which is why continuous monitoring is so valuable.
What unit is turbidity measured in?
Turbidity is measured in NTU, nephelometric turbidity units. AQUAIOT streams live NTU readings to the cloud and lets you set alert thresholds appropriate to treated water, distribution or process applications.
Can you measure very low turbidity?
Yes. Alongside the standard SPS-T-SC1 sensor, ultra-low turbidity variants are available for treated and final water where clarity must be held to tight limits.
Does it also measure suspended solids?
Yes. The same sensing detects suspended solids, which is particularly useful in wastewater and process water where particulate load is a key control and discharge parameter.

Catch the spike
the moment it starts.

Speak to an AQUAIOT engineer about continuous turbidity monitoring for your treatment, distribution or process water. No commitment required.

Hampshire-based · UK-wide deployment

UK engineering team. Responses within 1 business day.
Your data is handled in accordance with our Privacy Policy.

Message received.

Our engineering team will be in touch shortly. In the meantime, download the full datasheet below.

Download Datasheet
Shopping Cart (0 items)