Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611
AQUAIOT
MAC Valves UK Distributor

Replace dosing pumps
with precision
valve control.

MAC Liquid Bullet Valve BV214/BV221. Double-diaphragm, zero tubing, no pulsation. Supplied, installed and supported by AQUAIOT.

Authorised by MAC Valves Inc. for UK and Ireland
Scroll to explore
MAC LBV · Dosing Feed
Live
MAC Liquid Bullet Valve BV214 double-diaphragm dosing valve
12.4 Pulses/sec
0.02 Drift %
BV214 Valve Core
Dosing Active

The case for change

Why engineers are ditching small dosing pumps

Peristaltic and diaphragm pumps accumulate problems. MAC liquid dosing valves address each one.

01

Pulsation errors costing you compliance

Stroke-based pumps create pulsation at low flows, causing dosing inaccuracy, downstream mixing problems, and dose logs that cannot be defended in an audit.

02

Tubing failures and unplanned downtime

Peristaltic tubing splits under chemical exposure. Every failure means a reactive call-out, replacement parts, and a window where dosing has stopped entirely.

03

High maintenance across multiple failure points

Check valves, diaphragms, tubing, and motors all need regular servicing. Each failure point is a separate maintenance task and a separate cost line.

04

Accuracy drift as components wear

Pump accuracy degrades as internals wear. The further from original design point, the worse the drift — and the harder it is to keep dose logs within spec.

Engineering architecture

Four precision advantages inside every MAC Liquid Bullet Valve

Hover each capability to see the system respond in real time.

MAC LBV · Live System Monitor
Active
0.02 Drift %
12.4 Pulses/sec
OK Seal integrity
6.2 Bar inlet
Dual diaphragm isolating media · Chemical barrier active
MEDIA D-Flex D-Flex
01

Dual D-Flex Diaphragm

Media contacts only the diaphragm faces and valve body. No sliding seals, no o-ring rub, no tubing in the flow path. Chemical isolation by design.

PTFE / FKM / EPDM Media-separated No seal wear
P1 P2 Balanced
02

Balanced Poppet

Upstream pressure variation is equalised at the seat. Dosing volume per pulse stays consistent regardless of supply fluctuations, over the full life of the valve.

Pressure-independent Zero drift
ON OFF PWM · 4-20mA · On/off
03

High-Speed Solenoid Actuation

On/off switching, pulse-width modulation, or proportional control. Fast cycling creates near-continuous micro-dosing from a valve-sized footprint.

On/off & PWM Proportional 4-20mA
Multi-channel manifold block
04

Manifold Integration

A single block serves multiple dosing channels from one connection point, replacing the wiring, tubing, and floor space of individual pump assemblies.

Multi-channel Cartridge internals
10 bar
Max working pressure (app. dep.)
80°C
Operating temperature range
3 seals
PTFE, FKM (Viton), and EPDM options
UK Stocked
Standard cores held for rapid dispatch

Smart dosing integration

How AQUAIOT connects MAC valves to your water system

From sensor input to auditable dose log, in four steps.

1

Monitor

AQUAIOT sensors measure flow, conductivity, and water quality in real time. Data streams to the edge controller continuously.

2

Decide

Cloud logic and local edge rules calculate the dosing requirement against set-points, flow conditions, and time windows.

3

Dose

The MAC LBV fires precise solenoid pulses. Pulse width, frequency, and duration are all configurable from the AQUAIOT dashboard.

4

Prove

Every dose event is logged with timestamp, volume, and sensor context. Audit-ready exports for AMP8, Ofwat, and EA compliance.

Integration and control

Built for your existing infrastructure

SCADA and BMS

MODBUS RS485 and API connections. Direct integration with existing control systems without replacing your architecture.

Closed-loop dosing

Flow, conductivity, or quality sensor feedback adjusts dosing in real time. No manual trim, no operator intervention.

Compliance logging

Timestamped dose records. Exportable reports for AMP8, Ofwat performance commitments, and EA permits.

4G and LoRaWAN

Secure cellular telemetry. Encrypted payloads, over-the-air configuration, remote firmware updates.

PWM and proportional

On/off pulse, pulse-width modulation, or 0-10V / 4-20mA proportional control from one valve platform.

Cloud dashboard

Trendlines, alarms, analytics, role-based access, and data export from the AQUAIOT platform.

Use cases

Where MAC liquid dosing valves deliver results

Valve-grade accuracy in a compact footprint, across sectors.

Water and wastewater treatment

Coagulant, disinfectant, and side-stream dosing on treatment skids and booster stations. Integrates directly into SCADA control architectures.

Precise micro-dosing where larger pump-based systems cannot maintain accuracy at partial-load conditions.

Treatment & distribution

Agriculture and fertigation

Fertiliser injection into irrigation lines and drip systems. Consistent pulse volume tracks changing flow conditions.

Precision fertigation

Industrial and OEM

CIP dosing, detergent, cooling water treatment, and packaged plant. Manifold blocks reduce footprint and wiring.

OEM integration

Smart rainwater and SuDS

Additive dosing into smart water butts and attenuation tanks. IoT-triggered dosing on rainfall events.

Climate resilience

Technical overview

BV214 and BV221: full technical reference

Parameter BV214 BV221
Body size14mm21mm
Flow rangeMicro to low L/minLow to mid L/min
Max pressure~8 bar (app. dep.)~10 bar (app. dep.)
ActuationSolenoid: on/off, PWMSolenoid: on/off, PWM
ElastomersPTFE, FKM, EPDMPTFE, FKM, EPDM
Temp. range0 to 80°C0 to 80°C
ManifoldSingle / multi-channelSingle / multi-channel
ConnectionG-thread / customG-thread / custom
MediaWater, fertilisers, detergents, reagents, gases
Control signalOn/off, PWM, proportional (0-10V / 4-20mA)
ATEX variantsAvailable — contact us with zone classification

Exact specifications depend on body, orifice, and elastomer selection. Contact us for application-specific sizing and ATEX requirements.

Why choose AQUAIOT

Factory-authorised. Engineering-supplied. UK-stocked.

Authorised MAC Valves UK and Ireland distributor

As part of PSI Technologies, AQUAIOT holds factory-backed authorisation. We specify, stock, and support MAC dosing valves across the UK and Ireland.

Our engineers configure every build

Bespoke valve selection for unusual media, pressure, or manifold requirements. P&ID review included.

UK stock and rapid supply

Standard configurations held in UK inventory for rapid dispatch. No lengthy lead times on core SKUs.

End-to-end delivery

Hardware specification, IoT integration, cloud dashboard, commissioning, and ongoing support all from one team.

Open and interoperable

SCADA, BMS, CAFM, and AQUAIOT ecosystem integration via MODBUS, RS485, and API. No lock-in.

PSI Technologies Group

AQUAIOT operates as part of PSI Technologies, making us the exclusive MAC Valves partner for liquid dosing applications in the UK and Ireland. Every solution combines factory-authorised valve hardware with AQUAIOT IoT integration, cloud dashboards, and our own engineering team on every project.

  • Factory-authorised MAC Valves supply and specification
  • AQUAIOT IoT integration included as standard
  • UK-held stock for standard configurations
  • Engineering team covers design, install, and commissioning
  • Cloud monitoring, audit logging, and SCADA integration
  • Post-installation support and remote diagnostics

Dosing valve enquiry

Tell us about your site.

Share your site and monitoring needs. A UK engineer will follow up to scope the right approach.

AQUAIOT Page Enquiry

Your details go straight to our UK team at info@aquaiot.co.uk.

Response
One working day
Engineering
Survey, install, dashboards, training

Common questions

Questions about MAC liquid dosing valves

In many applications, yes. The MAC LBV suits micro-litre to low-L/min dosing within its pressure envelope. Our engineers will assess your P&ID and flow data to confirm feasibility before any commitment.
BV214 and BV221 cores cover micro-litre to low-L/min dosing at up to approximately 8 to 10 bar, depending on orifice, body, and elastomer selection.
The balanced poppet equalises upstream pressure variation. Dosing volume per pulse stays consistent regardless of supply pressure fluctuations, unlike pumps that drift with wear.
Water, fertilisers, detergents, chemical reagents, and gases. Seal options include PTFE, FKM (Viton), and EPDM, selected for your specific media at the design stage.
No tubing to replace, no check valves to service, no motor wear. Cartridge-replaceable internals mean field service without removing the valve from the manifold.
Yes. MODBUS RS485 and API connections for SCADA, BMS, CAFM, and the AQUAIOT cloud platform. Closed-loop control via flow, conductivity, or water quality sensor feedback.
MAC Valves manufactures ATEX and hazardous-area variants. Contact us for your specific zone classification requirements.
As part of PSI Technologies, AQUAIOT holds authorised MAC Valves UK and Ireland distributor status. UK stock for standard configurations, our own engineers for specification and installation, and complete IoT integration through the AQUAIOT platform.

Get started

Discuss your MAC dosing requirements

Tell us your application, flow rate, and media. Our engineers will size it, specify it, and support it.

We respond within one working day. No spam, no sales scripts.

Prefer to call? 02392 233611  ·  Full contact page

MAC Liquid Dosing Valves. UK-stocked. Installed and supported by AQUAIOT engineers.

Speak to an expert
Precision chemical dosing

Find the dosing valve for your chemical and duty

The valve meters into your existing line pressure instead of pumping against it, so there is no prime to lose and no tube to perish. Browse by application, chemical or the pump you are replacing.

Browse chemical dosing valves
Explore by chemical, application and comparison
Shopping Cart (0 items)