Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611

Continuous conductivity
monitoring. The fastest signal
of intrusion you have.

Real-time conductivity monitoring across distribution and source water. A sudden conductivity change is a rapid indicator of intrusion, cross-connection, saline ingress or chemical contamination.

UK-based engineering team Retrofit-friendly deployment Audit-ready records
Site Monitoring Live
pH
7.24
Potential of Hydrogen
Turbidity
0.42
NTU
Free Cl₂
0.08
mg/L
Dissolved O₂
8.71
mg/L
Conductivity
342
µS/cm

Example readings for illustration purposes

What you can’t see
is already costing you.

Reactive call-outs

Issues are flagged after damage is done, not before it starts. Every delayed alert is a cost you didn’t have to carry.

Fragmented compliance

Manual records, missed checks, and audit gaps across sites. When an inspector asks for evidence, the scramble begins.

Hidden drift

pH, chlorine, or turbidity can shift for days or weeks before anyone notices. Without real-time monitoring, you’re always reacting.

Continuous monitoring.
Instant alerts. Full audit trail.

Three connected layers that turn raw sensor data into actionable intelligence, automatically.

1. Monitor

Connected sensors stream real-time data across all parameters, 24 hours a day. Cellular and LoRaWAN telemetry with encrypted payloads.

2. Alert

Threshold breaches trigger instant SMS, email, or app notifications. Escalation rules and role-based routing ensure the right person acts.

3. Respond

Cloud dashboards give your team the data, trendlines, and records they need, instantly. Every reading logged, every action auditable.

Every parameter.
One connected system.

From standard chemistry to full-spectrum UV-Vis sensing, AQUAIOT covers every dimension of water quality your operation demands.

SPS-pH Water Quality Sensor
pH
SPS-pH Sensor

Continuous acidity and alkalinity monitoring. Detect corrosion risk, Legionella-risk conditions, and treatment performance drift.

Optimal drinking water pH: 6.5–9.5. Drift outside this range signals treatment failure or infrastructure issues.
SPS-T-SC1 Turbidity Sensor
Turbidity & Suspended Solids
SPS-T-SC1 Sensor

Detect particulate contamination, filter breakthrough, and process upsets in real time.

Turbidity spikes are often the first indicator of pipe disturbance, contamination ingress, or treatment failure.
SPS-CI Free Chlorine Sensor
Free Chlorine
SPS-CI-C Sensor

Continuous disinfection residual monitoring. Ensure treatment efficacy without manual sampling delays.

Chlorine residual below 0.1 mg/L creates microbial risk. Continuous monitoring catches drops before they become incidents.
SPS-DO Dissolved Oxygen Sensor
Dissolved Oxygen
SPS-DO Sensor

Monitor oxygen levels critical for biological process control, aeration efficiency, and environmental compliance.

Low DO in wastewater systems indicates biological stress; in distribution it can indicate contamination ingress.
SPS-EC Conductivity Sensor
Conductivity
SPS-EC Sensor

Track dissolved mineral content and detect contamination events, cross-connections, or treatment changes in real time.

Sudden conductivity changes are a rapid indicator of intrusion, saline ingress, or chemical contamination.
SPS-F Full Spectrum Water Quality Sensor
Full-Spectrum UV-Vis
SPS-F SpecSens Sensor

Specsens UV-Vis sensing at the edge. Detect organic load, humic substances, and complex contamination signatures beyond single-parameter sensors.

Full-spectrum sensing captures richer water quality signatures, ideal for source water characterisation and treatment optimisation.
SPS-Color-C Colour Sensor
Colour
SPS-Color-C Sensor

Detect apparent and true colour changes that may indicate natural organic matter, iron, manganese, or treatment by-products.

Colour is a key aesthetic and compliance parameter, continuous monitoring prevents visible discolouration events reaching consumers.
SPS-ORP Water Quality Sensor
ORP
SPS-ORP Sensor

Oxidation-reduction potential monitoring for disinfection effectiveness, redox conditions, and process control in treatment and distribution.

ORP is a direct measure of disinfection power, falling ORP values indicate that treatment residual is being depleted.

Want the full technical specifications for every sensor?

Download Datasheet

When something foreign enters the water, conductivity moves first.

Conductivity measures the dissolved ionic content of water, and it reacts almost instantly when that content changes. That speed makes it one of the most powerful early-warning parameters available. A sudden shift can reveal an intrusion event, a cross-connection between supplies, saline ingress at a coastal source, or chemical contamination entering the network.

AQUAIOT monitors conductivity continuously with the SPS-EC sensor, streaming live readings in microsiemens per centimetre to the cloud. Rapid-change detection and threshold alerts mean an abnormal step is flagged in real time, giving operators the chance to isolate and investigate a contamination event while it is still contained.

  • Continuous conductivity in microsiemens per centimetre
  • Rapid detection of intrusion and cross-connection events
  • Early warning of saline ingress and chemical contamination
  • Tracks treatment and blending changes across the network
At a glance

Conductivity monitoring specifics

MeasuresIonic / dissolved content
UnituS/cm
FlagsIntrusion, saline ingress
HardwareSPS-EC sensor
Speak to an Expert

Integrated monitoring systems,
not just sensors.

AQUAIOT combines connected sensors, cloud visibility, and engineering support into end-to-end deployments built around your infrastructure.

iSPA-T Multi-parameter Water Quality Monitoring System
iSPA-T
Multi-parameter Online Monitoring System

Integrated online monitoring system combining multiple sensing modalities, cloud telemetry, and dashboard connectivity in a single deployable unit.

View product
iSPS-X Multi-parameter Water Quality Instrument
iSPS-X
Multi-parameter Measurement Instrument

Versatile multi-parameter instrument supporting simultaneous measurement across key water quality indicators with flexible sensor configuration.

View product
SPA Chlorine Free/Total Chlorine Analyzer
SPA Chlorine Analyzer
Free & Total Chlorine Water Quality Analyser

Dedicated chlorine analysis with continuous free and total chlorine measurement, built for treatment, distribution, and compliance-relevant applications.

View product

From sensor edge to
operations dashboard

Every AQUAIOT deployment is built for the operational realities of UK water and estates teams, retrofit-friendly, open to your existing systems, and supported by engineers who understand what you’re monitoring and why.

  • Cellular + LoRaWAN telemetry with encrypted payloads
  • Over-the-air configuration & firmware management
  • RS485/Modbus · APIs for SCADA, AIMS/CAFM & analytics
  • Role-based dashboards, trendlines, alarms & exports
  • Exportable, audit-ready compliance records

Every reading. Every alert.
Every record. In one place.

Your monitoring data consolidated into a single cloud platform, built for operations, not just engineers.

AQUAIOT DASHBOARD · SITE OVERVIEW All Systems Normal
pH Current
7.24
↑ +0.02 vs 1hr ago
Free Cl₂
0.08
⚠ Low threshold
Turbidity
0.42
NTU · Normal
Free Chlorine — 24hr trend (mg/L)
Free Cl₂ approaching low threshold — Site A, Zone 3 14 mins ago
Daily compliance report generated — exported to CAFM 2 hrs ago
pH normalised after overnight treatment — all parameters within range 6 hrs ago
Real-time dashboards

Role-based cloud views with trendlines, threshold alarms, and multi-site visibility. Export data directly to your analytics stack.

Compliance records

Audit-ready trails generated automatically. Exportable logs and API integration with BMS, CAFM, and compliance platforms.

Intelligent alerts

SMS, email, and app notifications with escalation rules and role-based routing. Your team is notified before issues escalate.

Remote configuration

Over-the-air firmware updates and remote sensor configuration. Reduce site visits and keep systems current without disruption.

The engineering partner,
not just the hardware supplier.

AQUAIOT brings years of engineering experience alongside cutting-edge technology, so your deployment doesn’t end at the sensor.

End-to-end delivery

Site survey, installation, commissioning, dashboard setup, training, and post-installation support. We see it through.

Retrofit-friendly

Clamp-on ultrasonic flow meters and non-invasive sensors. No pipework cutting, no service shutdown, no disruption to live systems.

Open & interoperable

RS485/Modbus, APIs, SCADA, AIMS/CAFM integration. Built to connect, not to lock you in to a closed ecosystem.

UK engineering support

Hampshire-based team offering on-site and remote technical support. Real engineers, available when it matters.

Built for operational teams
who need to know.

Water quality monitoring isn’t one-size-fits-all. AQUAIOT deploys across the full range of UK water and estates operations.

Water Utilities Distribution monitoring, treatment compliance, and network resilience
Councils & Local Authorities Public infrastructure monitoring, drainage, and environmental oversight
NHS & Public-Sector Estates Legionella compliance, Legionella-risk monitoring, and audit-ready records
Housing Providers Large-scale Legionella and water quality monitoring across housing stock
Facilities & Asset Managers Estate-wide visibility with minimal manual intervention
Commercial Estates Water quality assurance, compliance support, and operational reporting

Conductivity monitoring questions

What does a sudden conductivity change mean?
A rapid shift in conductivity is a strong indicator that the dissolved content of the water has changed, which can mean intrusion, a cross-connection between supplies, saline ingress, or chemical contamination. Its speed of response makes it an excellent early-warning parameter.
What unit is conductivity measured in?
Conductivity is reported in microsiemens per centimetre. AQUAIOT streams live values to the cloud and lets you set alert thresholds and rapid-change detection appropriate to your source and network.
Where is conductivity monitoring most valuable?
At source and intake points to detect saline ingress, across distribution to catch intrusion and cross-connection, and in industrial settings to track process and blending changes.
How fast are contamination events detected?
Conductivity responds almost immediately to a change in ionic content, and AQUAIOT monitors it continuously, so an abnormal step can be alerted in real time rather than discovered at the next scheduled sample.

Catch intrusion
while it is still contained.

Speak to an AQUAIOT engineer about continuous conductivity monitoring across your source and distribution assets. No commitment required.

Hampshire-based · UK-wide deployment

UK engineering team. Responses within 1 business day.
Your data is handled in accordance with our Privacy Policy.

Message received.

Our engineering team will be in touch shortly. In the meantime, download the full datasheet below.

Download Datasheet
Shopping Cart (0 items)