Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611

Radar water level monitoring for tanks, sewers, rivers and ATEX sites

HOME › Services › Radar Level Monitoring UK
60GHz Radar Frequency
±2mm Accuracy
12m Max Range
7 yr Battery (LoRa)
IP68 Waterproof
ATEX Zone 0 Option

Radar water level sensor

The AQ41x-RDL is a non-contact radar distance and level sensor using 60GHz millimetre-wave technology. By measuring at higher frequencies it delivers stable, accurate readings over long distances, unaffected by temperature, dust, condensate, humidity, vapour or surface turbulence.

No wetted parts. No routine maintenance. IP68 sealed. Up to 7-year battery life. LoRaWAN® or cellular telemetry, configured on-site in minutes via NFC or Bluetooth.

Available in two variants: the AQ410-RDL (LoRa + Cellular) for standard deployments, and the AQ411-RDL (ATEX Zone 0, LoRa only) for hazardous area sites including sewers, fuel tanks and petrochemical bunds.

AQ41x-RDL installed in sewer chamber
Standard

AQ410-RDL

LoRaWAN® + Cellular: dual connectivity, maximum flexibility

  • LoRaWAN® (EU868, US915, AU915, AS923) or LTE Cat-1 cellular
  • ~7-year battery life on LoRaWAN® configuration
  • ~5-year battery life on cellular configuration
  • Operating temperature: −40°C to +70°C
  • IP68 sealed: 1m underwater for 48 hours
  • CE + FCC certified · RoHS compliant
  • Tanks, sewers, rivers, lagoons, bunds, industrial assets
⚠ ATEX Zone 0

AQ411-RDL

LoRaWAN® only: ATEX Zone 0 certified for explosive atmospheres

  • ATEX II 1 G Ex ia IIC T4 Ga, Zone 0 (most demanding ATEX category)
  • Intrinsically safe (Ex ia): supports most volatile gas groups (IIC)
  • ~7-year battery life
  • Operating temperature: −20°C to +60°C
  • IP68 + ATEX Zone 0 sealed enclosure
  • CE + FCC + ATEX (Zone 0) certified · RoHS compliant
  • Sewers, fuel tanks, bunds, petrochemical sites, DSEAR zones

Full Technical Specifications

All figures taken directly from the AQ41x-RDL product datasheet. Full ATEX documentation and individual model datasheets available on request.

Parameter AQ411-RDL (LoRa / ATEX) AQ410-RDL (LoRa) AQ410-RDL (Cellular)
Radar Parameters
TechnologyMillimetre Wave Radar
Radar Frequency60GHz
Beam Angle8°
Detection Range0.2m – 12m
Accuracy (still surface)±2mm
Accuracy (stable surface)±5mm
Resolution1mm
Target MediaLiquids or smooth-surfaced solids
Tilt MonitoringBuilt-in 3-axis accelerometer (Normal / Tilt status)
Wireless Transmission
Type LoRaWAN®LoRaWAN® LTE Cat-1 Cellular
Frequency Bands EU868 / US915 / AU915 / CN470 / IN865 / KR920 / AS923-1–4 EU868 / US915 / AU915 / CN470 / IN865 / KR920 / AS923-1–4 B1/B3/B5/B7/B8/B20/B28 (EMEA / AUS / NZ)
LoRa ModeOTAA / ABP Class AOTAA / ABP Class A—
Cellular Protocols——TCP / UDP / MQTT / AWS / Milesight Platform
SIM Slot——1× Nano SIM (4FF)
AntennaInternal (standard) or External (hardware optional)
Physical Characteristics
DimensionsØ101 × 87mm (Ø3.98 × 3.43 in)
Weight400g
MaterialPVDF (UL94 V0), Blue + Grey
Battery1× 19,000mAh ER34615 Li-SOCl₂
Battery Life ~7 years ~7 years ~5 years (15-min collection, 1440-report, 25°C)
Operating Temperature −20°C to +60°C −40°C to +70°C −35°C to +70°C
Humidity0–100% (non-condensing)
Ingress Protection IP68 + ATEX Zone 0 IP68 (1m, 48 hrs) IP68 (1m, 48 hrs)
Tank ThreadG 1½" or NPT 1½" (hardware optional)
InstallationWall bracket · Pole bracket · Tank threaded
Advanced Features
AlarmsDistance threshold · Distance change · Blind zone alarm
DiagnosticsRadar-echo curve · One-click distance calibration
Local Data Storage2,000 records + data retransmission (LoRa)
ConfigurationMobile app via NFC or Bluetooth
LED Indicator1× internal LED
Certifications & Compliance
Regulatory CE · FCC · ATEX Zone 0 CE · FCCCE
EnvironmentalRoHS compliant, all models

¹ ±2mm accuracy on perfectly smooth flat-surfaced solid or still liquid surface. ² ±5mm on relatively smooth or stable liquid surface. ³ Battery life tested under laboratory conditions, provided as guidance only.

Radar sensor key features

Built for the conditions UK sites actually present, not laboratory ideals.

🎯

±2mm Accuracy: Real Datasheet Numbers

8° focused radar beam targets the fluid surface precisely. ±2mm on a still surface; ±5mm on stable. 1mm resolution. No guesswork, just the spec from the datasheet.

📏

0.2m to 12m Range, Small Blind Zone

Wide range covers shallow sumps and deep tanks alike, with a minimal blind zone so you don't lose critical data near the sensor head.

🔋

Up to 7-Year Battery Life

19,000mAh Li-SOCl₂ battery. ~7 years on LoRa. ~5 years on cellular. Deploy at remote or hard-to-access assets and service the data, not the hardware.

🌊

Unaffected by Harsh Environments

Temperature, dust, condensate, vapour, acoustic noise, humidity: none of it affects the radar measurement. No drift from environmental change.

⚡

ATEX Zone 0: Highest Hazardous Area Rating

AQ411-RDL is rated Ex ia IIC T4 Ga. Zone 0 is the most demanding ATEX category, for locations with continuous explosive gas hazards, including the most volatile gas groups (IIC).

🛡️

PVDF Housing: Corrosion & Chemical Resistant

PVDF (UL94 V0) construction delivers corrosion resistance, wear resistance and compressive strength for aggressive liquids and harsh external environments.

📱

NFC + Bluetooth Configuration

Configure on-site via mobile app. No laptop, no specialist tools. One-click radar diagnostic and distance calibration before sign-off on every installation.

💾

2,000-Record Local Storage + Retransmission

Stores up to 2,000 historical readings locally. LoRa version supports retransmission on reconnect: patchy connectivity doesn't mean lost evidence.

📐

Built-In 3-Axis Accelerometer

Continuously monitors device tilt status. If the sensor position shifts (from vibration, water movement or mechanical change), you'll know before it affects your readings.

Certifications & Compliance

Full documentation available on request for procurement, DSEAR risk assessments and regulated site approvals.

CE
EU/UK conformity marking, all models
FCC
US Federal Communications Commission: AQ410 & AQ411
ATEX
Zone 0
AQ411-RDL only. Ex ia IIC T4 Ga, intrinsically safe
RoHS
Restriction of Hazardous Substances, all models

Industries We Support

Wherever there's a liquid level that matters and a team that needs to know before something goes wrong.

💧

Water Utility

Continuous level intelligence across drainage networks with evidence trails for regulatory reporting.

  • Sewers, manholes, wet wells and storm tanks
  • CSO/spill hotspot visibility: level + rate-of-rise alarms
  • River and channel monitoring for flood resilience
  • EDM-aligned evidence for storm overflow reporting
⛏️

Quarry, Mines & Aggregates

Stay ahead of run-off, pump failures and pollution incidents at remote sites.

  • Settlement lagoons, silt ponds and run-off control
  • Mine sumps and dewatering points
  • Wash-plant tanks and process water storage
  • Fast-rise alarms for emergency pumping response
🏭

Food & Beverage

Process tanks and effluent holding where levels change quickly during cleaning and production cycles.

  • Process and utility tanks with high/low alarms
  • Effluent holding and discharge management
  • Trade effluent compliance monitoring
  • FOG drain risk reduction
⛽

Petrochemical & Fuel

Fuel storage and flammable liquid sites where DSEAR compliance and ATEX certification are essential.

  • Fuel tanks and bunds: AQ411-RDL ATEX Zone 0
  • Remote sites requiring dependable cellular telemetry
  • High/low alarms and trend evidence for governance
  • DSEAR-aligned deployment (model and site dependent)
🔧

General Industrial & Manufacturing

Multiple tanks, bunds and interceptors: costly to inspect manually, risky to leave unmonitored.

  • Chemical storage tanks, IBC compounds, containment
  • Effluent and wastewater tanks and site drainage
  • Bund accumulation monitoring
  • Operational evidence for compliance and governance
🌧️

Rainwater Harvesting & SuDS

Smart management of rainwater and sustainable drainage assets. Keep storage in the right window, automatically.

  • Smart water butt and rainwater tank monitoring
  • SuDS attenuation basins and retention ponds
  • IoT dashboard for remote estate management
  • Overflow risk and low-storage alerts

Water level alarms

Not just "high" and "low". Alarm rules that catch developing incidents, not ones that have already happened.

High / Low Thresholds

Simple, fast to deploy. Set upper and lower limits for any asset. Immediate alert on breach. Standard for every deployment.

Rate-of-Change Alarms

Sudden level rise can indicate inflow surge, pump failure or blockage, before the threshold is hit. Catch incidents earlier, intervene faster.

Persistence Rules

Only escalate when a condition persists. Filters out transient spikes. Fewer false call-outs, more confident response when alarms fire.

Blind Zone Alarms

Alert when ranging results fall within the blind zone, a sign the asset may be near overflow or the sensor needs repositioning.

Where is radar level monitoring used?

Radar level monitoring suits any water or liquid surface you cannot watch in person: tanks, sewer wet wells, storm overflow chambers, rivers, reservoirs and gullies. Because the AQUAIOT Radar never touches the water, the same sensor works in a clean reservoir and a foaming sewer chamber.

Radar level monitoring by application
ApplicationWhat it watchesGuide
Covered and open tanksLevel, fill and overfill, including fuel and chemical tanksRemote tank level monitoring
Sewer wet wells and pumping stationsLevel rising towards overflow or pump failurePumping station monitoring
Storm overflow and sewer chambersLevel and spill start and stop in enclosed, humid chambersSewer and drain monitoring
Rivers and watercoursesRiver level against flood thresholdsRiver level monitoring
Reservoirs and pondsStorage level and freeboardReservoir level monitoring
Gullies and surface waterWater backing up before a road floodsSmart gully monitoring
Hazardous areasLevel in ATEX-classified tanks and chambers (AQ411-RDL)ATEX level sensors

Choosing between radar and ultrasonic? Our radar vs ultrasonic comparison sets them side by side. For alarms and siting on flood-risk sites, see the radar water level sensor for flood monitoring guide.

How Deployment Works

Designed for operational teams, not specialist RF engineers. From a single asset to estate-wide rollouts.

1
Scope the Asset

Identify asset type, measurement range needed, and whether the site is a hazardous area (DSEAR/ATEX). We confirm the right model, connectivity and mounting.

2
Agree Alarm Logic

Define thresholds, rate-of-rise rules and persistence filters. Set escalation contacts. This step prevents nuisance alarms and ensures every alert triggers real action.

3
Choose Connectivity

LoRaWAN® for estate-wide or network coverage. Cellular for standalone or remote assets without LoRaWAN infrastructure. We advise. You don't have to guess.

4
Install and Verify

Mount via wall bracket, pole bracket or tank thread (G 1½" or NPT 1½"). Configure via NFC or Bluetooth app. Run one-click diagnostic. Alarm test before sign-off.

5
Operate with Confidence

Live level trends, alerts and reporting via your IoT dashboard. 2,000 records stored on-device with retransmission, so connectivity gaps don't create data gaps.

Connectivity Options

LoRaWAN® or Cellular (LTE Cat-1), matched to your site, asset count and operational response needs.

LoRaWAN®

Best for estate-wide or network rollouts

  • Low-power, long-range network coverage
  • Ideal where one gateway covers multiple assets
  • Up to 7-year battery life, longest service interval
  • EU868 / US915 / AU915 / AS923 and global bands
  • OTAA / ABP Class A, integrates with standard gateways
  • Data retransmission on reconnect: no silent data gaps
  • Available on AQ410-RDL and AQ411-RDL (ATEX)

Cellular (LTE Cat-1)

Best for standalone or remote assets

  • No LoRaWAN gateway infrastructure required
  • Ideal for isolated assets and rapid single-site deployment
  • ~5-year battery life (15-min collection, 1440-report interval)
  • B1/B3/B5/B7/B8/B20/B28: UK, EMEA, AUS/NZ bands
  • 1× Nano SIM (4FF): standard SIM, no custom hardware
  • TCP / UDP / MQTT / AWS / Milesight platform support
  • Available on AQ410-RDL only

Ordering Information

Standard configuration ships with G 1½" thread and internal antenna unless specified. Contact AQUAIOT to confirm model, variant and ATEX documentation requirements.

EM41x-RDL

G 1½" thread
Internal antenna
Standard

EM41x-RDL/EA

G 1½" thread
External antenna
For challenging RF environments

EM41x-RDL/NPT

NPT 1½" thread
Internal antenna
For NPT-threaded tanks

EM41x-RDL/EA-NPT

NPT 1½" thread
External antenna
Combined NPT + EA variant

x = 0 (standard) or 1 (ATEX). ATEX Zone 0 available on AQ411-RDL only. Confirm ATEX variant and site classification with AQUAIOT before ordering for hazardous area use.

Radar level monitoring enquiry

Tell us about your site.

Share your site and monitoring needs. A UK engineer will follow up to scope the right approach.

AQUAIOT Page Enquiry

Your details go straight to our UK team at info@aquaiot.co.uk.

Response
One working day
Engineering
Survey, install, dashboards, training

Water level monitoring FAQs

Answered with the actual specifications, not vague reassurances.

What is the accuracy of the AQ41x-RDL?
±2mm on a still or perfectly smooth liquid surface. ±5mm on a stable but not perfectly still surface. Resolution is 1mm. These are datasheet-specified figures. Accuracy in the field depends on correct mounting, surface type and the presence of foam or floating debris. We scope each installation to achieve stable readings.
How long does the battery last?
LoRaWAN® models (AQ410-RDL and AQ411-RDL): approximately 7 years. Cellular model (AQ410-RDL cellular): approximately 5 years at a 15-minute collection interval with 1,440-report interval at 25°C. Figures are from laboratory testing. Actual life depends on reporting interval and ambient temperature.
What is the detection range?
0.2m to 12m. This covers the majority of UK tank, chamber, lagoon and sewer monitoring applications. The 8° beam angle minimises interference from walls or structures inside confined chambers.
Is the sensor affected by condensation, steam or turbulence?
No. The 60GHz millimetre-wave radar is non-contact and unaffected by temperature variation, dust, condensate, humidity, vapour, acoustic noise or surface turbulence. This is one of the key reasons radar is preferred over ultrasonic or pressure-based alternatives in drainage, industrial and outdoor applications.
What does ATEX Zone 0 mean in practice?
The AQ411-RDL carries ATEX marking II 1 G Ex ia IIC T4 Ga. Zone 0 is the most demanding category: locations where explosive gas is present continuously or for long periods. Ex ia (intrinsic safety) and Group IIC supports the most volatile gases including hydrogen. Selection and installation must be carried out by a competent person in line with your site's DSEAR/ATEX assessment.
LoRaWAN® or cellular: which should we choose?
LoRaWAN® for estate-wide rollouts: longer battery, lower power, scalable where you have or plan a gateway. Cellular for standalone or remote assets without LoRaWAN infrastructure. We review your sites and recommend the right option. There's no charge for that advice.
What happens if connectivity is lost? Is data preserved?
Yes. The sensor stores up to 2,000 historical records locally. The LoRaWAN® version supports data retransmission on reconnect, so readings taken during an outage are recovered automatically, important for compliance-critical sites and evidence-based reporting.

Talk to an Engineer