Worked example · Factory plant roomsA worked example
The plant room closed its own supply at 02:14, more than five hours before anyone arrived.
In this worked example, a braided hose on a water softener splits in the middle of the night on a process water supply. A leak sensor on the floor gets wet, the controller closes the shut-off valve on the supply within seconds, and the duty engineer gets a text. The site and the figures are an example, not a customer installation. Play the night both ways to see what reached the floor.
- Process water
- Closes without the network
- Text to the duty engineer
02:10. The plant room is dry. Press play.
An example night with example figures: a 12 L/min leak from 02:12, found at 07:40.
Minute by minute
The valve did its job before anyone had read the text.
The alarm reached the duty engineer at 02:14 either way. The difference is what the water did between the text and the morning.
07:40. The engineer arrives.
A softener hose splits.
Water sprays from the braided hose at 12 litres a minute and runs across the floor.
The sensor at the low point gets wet.
The controller’s own rule closes the supply valve within seconds, without waiting for the network.
The duty engineer gets a text.
It names the plant room and the sensor, and says the supply is closed, so nobody needs to drive in at night.
The water stops.
Only the water left in the pipe after the valve drains out, about 8 litres. With the 24 litres of the first two minutes, 32 litres reach the floor in all.
The engineer arrives.
The floor needs a towel and the softener a new hose. The sensor is dried, the controller is reset on site and the water is turned back on.
This is how the two figures add up.
12 L/min for the 2 minutes before the sensor got wet is 24 L, plus about 8 L left in the pipe after the valve.
12 L/min for the 328 minutes from 02:12 to 07:40, when the engineer arrives and turns the water off.
How it is wired
Everything that closes the valve is wired, so it works with the network down.
The sensors are wired to the controller’s inputs and the valve coil to its relay. The rule that closes the valve runs inside the controller, so a wet sensor closes the supply even if the radio link is down. The radio only carries the text and the record.
- Three sensors at the floor’s low points
- 1 1/4 inch valve, 24 V DC coil
- Controller with relay output
- Text by LoRaWAN or 4G
What the example site chose
The site decided how cautious the shut-off should be.
The same hardware can close on the first drop or wait for proof. These are the choices this plant room made, and why.
On the first wet sensor.
The plant room is unmanned at night and nothing in it needs the supply to run, so there is no reason to wait.
Stay closed until reset on site.
The water never comes back onto a wet floor by itself; someone looks first.
The duty engineer and the facilities manager.
The text says the supply is already closed, so nobody has to drive in at night.
The kit in this example
This is the kit fitted in the example plant room.
Pricing is by quotation, depending on the pipe size, the number of sensors and the signal reach. This is the list we would cost for a similar room.
Wired leak sensors
At the floor’s low points, where a leak runs first.
3 sensorsController
Sensor inputs, a relay for the valve, and LoRaWAN or 4G for the text.
1 controllerAQUAIOT dashboard
Every wet sensor, every close and every reset, with the time.
1 siteQuestions
These are the questions engineers ask before fitting a shut-off.
What if a pump in the plant room depends on that supply?
We check it before the valve goes in. A process pump fed from the closed supply needs its own dry-run protection, so it stops when its water stops. Where it has none, we wire the shut-off to stop the pump as well.
What happens in a power cut?
The standard valve is normally closed, so the supply closes when the power goes. Sites that must keep water through a power cut choose the normally open version, made to order, which closes only on command.
Will cleaning water set it off?
It can, which is why the sensors sit at the low points where a leak runs, not where the floor is mopped. The site can also choose a rule that needs two sensors wet, or a short delay, before the valve closes.
Can it go on a drinking-water supply?
No. This example is on process water. Fittings on a drinking-water supply have to meet the Water Supply (Water Fittings) Regulations 1999, and we do not offer a WRAS-listed valve with this system.
How is the water turned back on?
In this example the valve stays closed until someone on site dries the sensor and resets the controller, so the water never comes back onto a wet floor by itself. Remote reset is possible if the site prefers it.
Speak to an expert
Tell us about your plant room and we will plan the shut-off.
An AQUAIOT engineer will look at the supply, the pipe size, any pumps it feeds and where a leak would run, then propose the sensors, the valve and the rules.
- Plant room surveySupply, pumps, low points and pipe size checked first.
- Fitted and testedWe wet a sensor and watch the valve close before handover.
- Rules you chooseClose on the first drop, or wait for proof.