Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611

Pump Hire Flow Monitoring: How AQUAIOT and Exsel Pumps Fitted a Clamp-On Flow Meter in Luton

TL;DR: Pump hire flow monitoring means a hire company can read how much liquid a pump is moving without sending anyone to site. AQUAIOT and Exsel Pumps have teamed up on a first install at a site in Luton. An ultrasonic flow meter clamps to the outside of the pipe, so nothing is cut and the pump keeps running. A telemetry unit in a cabinet sends flow rate and total volume to a cloud dashboard that can be opened from anywhere.

Last updated: 27 October 2026

Key takeaways

  • Pump hire flow monitoring replaces a trip to the pipe with a reading on a cloud dashboard.
  • The sensors strap to the outside of the pipe, so there is no cutting, no downtime and no service interruption.
  • The meter records flow rate and total volume, and the telemetry unit sends them to the AQUAIOT dashboard, so pump hire flow monitoring includes alerts, warnings and reports.
  • The first install is at a site in Luton, built with Exsel Pumps, an independent UK pump hire specialist.

Exsel Pumps is an independent UK pump hire specialist that works on temporary pumping, including sewage and other complex applications. Until now, getting a flow reading from a hired pump meant a visit to site to download or inspect a physical meter. We worked with the Exsel Pumps team to change that, starting with a site in Luton. This post walks through pump hire flow monitoring at Luton: what we fitted, how it measures, and what it means for a hire fleet.

An AQUAIOT engineer in orange hi-vis walks beside steel pump pipelines laid across open ground at the Exsel Pumps site in Luton
An AQUAIOT engineer walks the pipeline at the Exsel Pumps site in Luton.

What is pump hire flow monitoring?

Pump hire flow monitoring is the continuous measurement of how much liquid a hired pump is moving, sent automatically to a dashboard instead of being read at the pipe. It records flow rate and total volume, so the hire company and its customer can see what a pump is doing without anyone standing beside it.

The idea is simple. The hard part of pump hire flow monitoring is doing it on temporary pipework, on a working site, without stopping the pump or cutting into the line. That is why the Luton install uses a clamp-on meter.

Why does a hire fleet need flow readings without a site visit?

Exsel needed flow readings from its hired pumps without sending staff to site to read them, because its contracts call for those readings. Reading a meter by hand means a trip to the pipe, and the pipe is often on a live site with plant moving, open excavations and temporary pipework.

Steel pipework and heavy hoses meeting in a shored excavation at the Luton site where the pumps work
Pipework and hoses in a shored excavation, the kind of site where reading a meter by hand is a trip.

Remote pump hire flow monitoring removes that trip. The same figures reach the hire desk and the customer at the same time, wherever they are working. Exsel is introducing real-time flow metering to its hire fleet, and Luton is the first site. For a hire business, that makes pump hire flow monitoring a way to give customers readings on demand rather than on a visit schedule.

How does a clamp-on ultrasonic flow meter measure flow?

A clamp-on ultrasonic flow meter uses two sensors on the outside of the pipe. Each sends a short pulse through the liquid to the other. A pulse travelling with the flow arrives slightly sooner than one travelling against it, and that difference in transit time reflects the average velocity of the liquid. This is the transit-time method, described in more detail on Wikipedia.

The meter turns that velocity into a flow rate using the size of the pipe, then adds it up over time to give total volume. Because the sensors sit on the outside, nothing enters the liquid. There is no section of pipe to cut out and no meter body in the flow to block.

At Luton the sensors are arranged in a W pattern. The signal crosses the pipe several times between the two sensors, which lengthens the path it travels through the liquid. Fixing them with straps takes a short time compared with fitting an in-line meter, which is why the method suits pump hire flow monitoring on temporary pipework.

Clamp-on ultrasonic flow sensor strapped to the outside of a large steel pump pipeline with cable ties and a lead running away from the pipe
A clamp-on sensor strapped to the outside of the pipe. Nothing is cut.

What did AQUAIOT install at the Luton site?

For this pump hire flow monitoring install, we built a cabinet with a clamp-on ultrasonic flow meter and a telemetry unit, and strapped the sensors to the pump pipeline. The pipe is a large steel line laid across open ground, next to plant and excavations. Nothing was cut and the pump kept running. The same approach is described on our clamp-on ultrasonic flow meter service page.

Second view of the flow sensor fixed to the pump pipeline, with straps running around the pipe and the pipe flange in the background
The same pipeline from further back, with the sensor strapped in place.

The cabinet stands on a steel frame next to the pipe. Inside are the flow meter electronics and the telemetry unit, with the sensor cables running back to it. Keeping everything in one cabinet makes the pump hire flow monitoring kit a single, tidy unit.

Pump hire flow monitoring cabinet with its door open beside a steel pipeline, showing the flow meter electronics, the telemetry unit and the sensor cables
The AQUAIOT cabinet holds the flow meter electronics and the telemetry unit.

The pump set itself is Exsel’s own hire equipment, connected with suction and discharge hoses in the normal way. The flow meter did not change how the pumps are set up. It adds a reading to a system that was already working, which is the point of pump hire flow monitoring.

Exsel branded pump set on site with suction and discharge hoses connected and an engineer's tool case and meter in the foreground
The Exsel pump set on site, ready for pump hire flow monitoring.

How do the readings reach the dashboard?

A telemetry unit in the AQUAIOT control cabinet sends the readings to a cloud dashboard. From there they feed alerts, warnings and reports, and they can be opened from anywhere with a web connection. Nobody has to be at the pipe to see what the pump is doing, which is what pump hire flow monitoring is for.

The same cloud layer sits behind our other monitoring work, so a hire company running pump hire flow monitoring can see flow alongside other signals. For sewage and wet well duties, for example, flow readings can sit next to level readings from sewer monitoring. We call the layer the AQUAIOT dashboard, and it is built for the people who run the pumps rather than for a showroom.

Where does clamp-on metering suit hired pumps?

Clamp-on metering suits pump hire flow monitoring wherever there is a clear length of accessible pipe and the readings are needed without a visit. It is a retrofit method, so it works on pipework that is already installed and running. Our post on retrofitting clamp-on ultrasonic flow meters covers the general case.

Pump hire flow monitoring is not a one-size-fits-all fit. Conditions at the pipe matter: the pipe wall, the liquid and the access. Wikipedia notes that ultrasonic meters can be affected by the acoustic properties of the fluid, its temperature, density and viscosity, and by suspended particles, depending on the design. So we check the pipe and the duty before promising a result, and our guide on how accurate a clamp-on flow meter is explains what affects the reading.

For a hire fleet the practical benefits are straightforward:

  • Fewer trips to site just to read a meter.
  • The same numbers in front of the hire desk and the customer at the same time.
  • No cut in the pipe and no stop for the pump to fit the meter.
  • One dashboard for alerts, warnings and reports instead of paper readings.

Frequently asked questions

Does the pump have to stop to fit a clamp-on flow meter?

No. The sensors fit on the outside of the pipe, so there is no cutting, no downtime and no service interruption. The pump keeps working while the meter is installed.

What does pump hire flow monitoring record?

It records flow rate and total volume. The telemetry unit in the cabinet sends both to the AQUAIOT cloud dashboard, which also provides alerts, warnings and reports.

Can a hire company see the readings from the office?

Yes. The readings sit on a cloud-hosted dashboard that can be accessed from anywhere, so nobody needs to go to site to download or inspect a meter.

How does a clamp-on sensor measure flow without touching the liquid?

It uses the transit-time method. Two sensors send ultrasonic pulses through the pipe wall and the liquid, one with the flow and one against it. The time difference between them reflects the velocity of the liquid.

Is clamp-on metering suitable for every pump hire job?

Not automatically. For pump hire flow monitoring the pipe wall, the liquid and the access all affect the result, so we check the pipe and the duty first. Talk to us about the site before choosing a meter.

Talk to AQUAIOT about your pumps

If you want pump hire flow monitoring across a hire fleet, or a site where pumps work unattended, discuss your site with AQUAIOT. Tell us the pipe, the duty and where the readings need to go, and we will advise whether a clamp-on meter fits. Thank you to the Exsel Pumps team for working with us on this first install.

Previous Post
Newer Post
Shopping Cart (0 items)