Leak Sensor

Leak Shut-Off Kit

  • Up to four sensors
  • Relay output
  • LoRaWAN or 4G

Price on request

Prices are in pounds sterling and exclude VAT. Our quotes are valid for 30 days.

We typically reply within one working day. Or call 023 9223 3611

A leak shut-off kit from AQUAIOT, planned, fitted and tested as one quote. Wired leak sensors, a controller with a relay output and a brass shut-off valve, sized to your pipe and quoted as one line. When a sensor gets wet, the controller closes the valve on its own and tells your team.

  • Up to four wired leak sensors on one controller
  • The controller closes the valve on site, even if the network is down
  • Brass shut-off valve, 3/8 to 2 inch, water 0 to 5 bar
  • Alerts over LoRaWAN or 4G
  • For process water, cooling water, wash-down and irrigation, not drinking water

Pricing by quotation. Build your kit below, or see how the automatic shut-off system works.

Valve sizes

3/8 to 2 inch, water 0 to 5 bar

  • Wired Leak Sensors
  • Controller with Relay Output
  • Brass Shut-Off Valve

Ordering and assurance

  • Prices in pounds, ex VAT
  • Delivery charged as quoted
  • Proforma invoice or 30 days on account
  • Manufacturer's warranty

Installation, commissioning and site surveys available. Quotes valid for 30 days. Terms and conditions

Questions about this product? Call 023 9223 3611 or email info@aquaiot.co.uk

Build your kit

Answer five questions and the kit list builds itself.

Pick the pipe, the number of sensors and how cautious the shut-off should be. The diagram lights up each part as you choose, and the kit list it builds is what we would quote. Send it with your quote request in one click.

For process water, cooling water, wash-down and irrigation. The valve is not WRAS listed, so the kit is not for drinking-water supplies.

01Which pipe does the supply run in?

Copper sizes are shown with the thread the valve uses on that pipe.

02How many places could a leak start?
2

One sensor at each low point where water would gather. One controller takes up to four.

03When should the valve close?
04What should happen if the power fails?
05Which coil voltage suits the site?

Your kit

Leak shut-off kit for a 1 inch supply

The kit as a diagram: wired leak sensors on the left feed the controller in the middle, and the controller’s relay drives the shut-off valve on the rightControllerCloses on 1st wetRule runs on site24 V DC1 inchNormally closedAlert sent

Tap or click a sensor in the diagram to test the rule you picked.

  • 1

    Shut-off valve, 1 inch

    Rc 1 brass, orifice 25 mm, Cv 12, normally closed, 24 V DC coil with DIN plug.

  • 2

    Wired leak sensors

    One at each low point, wired to the controller’s inputs.

  • 1

    Controller with relay output

    Rule: close on the first wet sensor. Alerts by email or SMS over LoRaWAN or 4G.

  • 1

    24 V DC power supply

    Runs the controller and the 18 W valve coil.

  • 1

    Fitting and testing

    Survey, installation, a wet-sensor test and handover.

Quoted as one line after a short survey. Prices are by quotation.

4sensors

Wired sensors per controller

One on each input

3A

Relay rating

At 30 V DC or 250 V AC

3/8 to 2inch

Valve sizes

Seven sizes, Cv 4.8 to 48

0 to 5bar

Water pressure

−5 to 80 °C

LoRaWANor 4G

How the alert travels

The rule itself runs on site

The three parts

Each part has one job, and the wiring joins them up.

The sensors are wired to the controller’s inputs and the valve coil to its relay. The rule that closes the valve runs inside the controller, so a wet sensor closes the supply even if the radio link is down.

  1. Detect

    Wired leak sensors find the water.

    They sit at the low points where a leak would run first, one on each of the controller’s four inputs.

    Wired leak sensors

  2. Decide

    The controller decides what to do.

    It runs the rule on site, switches the valve through a relay rated 3 A, and reports over LoRaWAN or 4G.

    Controller with relay output

  3. Close

    The shut-off valve closes the supply.

    A brass 2-way solenoid valve, 3/8 to 2 inch, for water from 0 to 5 bar and −5 to 80 °C. See the valve in each size.

    Automatic shut-off valve

The brass shut-off valve used in the kit, shown with a fixed lead on the left and a DIN plug on the right
The kit’s valve, in two versions: a fixed lead on the left and a DIN plug on the right. Every size and figure for the valve.

Drinking water

The kit is not for drinking-water supplies.

Fittings on a drinking-water supply have to meet the Water Supply (Water Fittings) Regulations 1999, and the kit’s valve is not WRAS listed. It is for process water, cooling water, wash-down and irrigation.

Installation

An engineer fits and proves the kit in one visit.

The rules, the people who are told and the way the supply is reset are agreed with you before handover.

  1. Survey the supply.

    We check the pipe and thread, the pressure, the branch to close and any pump the supply feeds.

  2. Fit the valve.

    The branch is isolated and drained, and the valve goes in the right way round for the flow.

  3. Place and wire the sensors.

    Each sensor goes at a low point and is wired to one of the controller’s inputs.

  4. Prove the shut-off.

    We wet a sensor, watch the valve close, check the alert arrives and reset the supply.

If a pump draws from the supply the valve closes, we check it has its own dry-run protection before the valve goes in, or wire the shut-off to stop the pump as well.

  • Survey before ordering
  • Fitted by an engineer
  • Tested before handover
  • Supported after go-live

Questions

These are the questions we hear before a kit is ordered.

Would you rather talk it through with an engineer?

Call 023 9223 3611 or email info@aquaiot.co.uk.

Can the kit go on a drinking-water supply?

No. Fittings on a drinking-water supply have to meet the Water Supply (Water Fittings) Regulations 1999, and the kit’s valve is not WRAS listed, so the kit is for process water, cooling water, wash-down and irrigation.

How many sensors can one controller take?

Up to four wired leak sensors, one on each of the controller’s inputs. Larger areas are planned at the survey.

Does it need the internet to close the valve?

No. The sensors and the valve are wired to the controller, and its own rule closes the valve on site. The network only carries the alert and the record.

Which coil voltage should we choose?

The 24 V DC coil is the usual choice, because the same 24 V supply runs the controller and the controller’s relay switches the coil directly. 110 V AC and 220 V AC coils suit sites that prefer to switch mains, and an electrician wires them.

Is it priced as one item?

Yes. The kit is quoted as one line after a short survey, including the sensors, the controller, the valve, the power supply, fitting and testing.

See how the whole shut-off system works.

The system page walks through every part of the kit, and the valve page lists each size with its figures.

Price on requestTypical reply: one working day