Water Management
Automatic Shut-Off Valve 3/8 to 2 Inch
- Forged brass
- Normally closed
- Water 0 to 5 bar
Choose the size
Price on request
Prices are in pounds sterling and exclude VAT. Our quotes are valid for 30 days.
We typically reply within one working day. Or call 023 9223 3611
An automatic shut-off valve for AQUAIOT leak shut-off systems. A brass 2-way solenoid valve for process water, cooling water and wash-down lines. When an AQUAIOT leak sensor gets wet, the controller switches its relay and the valve closes the supply.
- Seven sizes, Rc 3/8 to G 2, flow factor Cv 4.8 to 48
- Water 0 to 5 bar, air 0 to 7 bar, fluid −5 to 80 °C
- Normally closed; normally open made to order
- 24 V DC, 110 V AC or 220 V AC coil, DIN plug or fixed lead
- Not WRAS listed: for process water, cooling water, wash-down and irrigation
Pricing by quotation. How the automatic shut-off system works.
Flow factor
Cv 4.8 to 48, by size
- Forged Brass Solenoid Valve
- Closes on a Leak Alarm
- Seven Sizes, 3/8 to 2 Inch
Not sure the shut-off valve is right for your site?
Ordering and assurance
- Prices in pounds, ex VAT
- Delivery charged as quoted
- Proforma invoice or 30 days on account
- Manufacturer's warranty
Solutions this product serves
Overview
It is the part of the system that actually stops the water.
Leak sensors find the water and the controller decides what to do. This valve is what closes the supply. It is a direct-acting diaphragm valve, so it works from 0 bar upwards and suits gravity-fed supplies as well as pressurised lines up to 5 bar.
It is normally closed as standard: the coil holds it open, and it closes when the controller cuts the power to the coil, or when the site loses power. A normally open version is made to order for supplies that must stay on without power.

Pick a number on the photo, or a part in this list, to see its figures.
- Coil voltages
- 24 V DC, 110 V AC or 220 V AC
- At 24 V DC, 3/8 to 1 inch
- 18 W
- At 24 V DC, 1 1/4 to 2 inch
- 50 W with a fixed lead, 48 W with a DIN plug
- Minimum energising time
- 0.05 s
The coil holds the valve open while it is powered. When the controller’s relay cuts the power, or the site loses power, the valve closes.
- Connection
- DIN terminal plug
- Suits
- Easy replacement
The cable is wired into a DIN terminal plug on the side of the coil, so the plug comes off for easy replacement.
- Connection
- Grommet with a fixed lead
- Suits
- Tight spaces
The lead comes straight out of the coil through a grommet, so there is no plug to make room for. It suits tight spaces.
- Diaphragm
- NBR, Viton or silicone
- Valve type
- 2/2 way, direct diaphragm
- Orifice
- 16 to 50 mm, by size
- Spring
- Stainless steel
It sits inside the body and opens and closes the orifice. The valve is direct acting, so it works from 0 bar, with no minimum pressure.
- Body
- Forged brass
- Water
- 0 to 5 bar (0 to 500 kPa)
- Air
- 0 to 7 bar (0 to 700 kPa)
- Fluid and ambient
- −5 to 80 °C
It is not for high-temperature liquids, liquids that set solid as they cool, corrosive fluids or fluids thicker than 20 cSt.
- Tapered thread
- Rc 3/8, Rc 1/2, Rc 3/4, Rc 1
- Parallel thread
- G 1 1/4, G 1 1/2, G 2
- Flow factor
- Cv 4.8 to 48
Seven sizes from 3/8 inch to 2 inch. Choose the size that matches the pipe.
0 to 5bar
Water pressure
Air 0 to 7 bar
−5 to 80°C
Fluid and ambient temperature
Not for high-temperature liquids
4.8 to 48
Flow factor (Cv), by size
Orifice 16 to 50 mm
0.05s
Minimum energising time
Coil 24 V DC, 110 V or 220 V AC
NC
Normally closed
Normally open made to order
Sizes
Choose the size that matches the pipe.
All seven sizes share the same pressure and temperature rating and the same coil voltages. A bigger orifice passes more water, and the flow factor (Cv) shows how much more. Pricing is by quotation, depending on the size, the coil and the rest of the shut-off system.
3/8 inch
Rc 3/8 port, tapered thread
- Orifice
- 16 mm
- Flow factor
- Cv 4.8
- Coil power at 24 V DC
- 18 W
- Weight
- 0.88 to 0.91 kg
The bar shows the flow factor against Cv 48, the 2 inch valve.
1/2 inch
Rc 1/2 port, tapered thread
- Orifice
- 16 mm
- Flow factor
- Cv 4.8
- Coil power at 24 V DC
- 18 W
- Weight
- 0.88 kg
The bar shows the flow factor against Cv 48, the 2 inch valve.
3/4 inch
Rc 3/4 port, tapered thread
- Orifice
- 20 mm
- Flow factor
- Cv 7.6
- Coil power at 24 V DC
- 18 W
- Weight
- 0.90 to 0.91 kg
The bar shows the flow factor against Cv 48, the 2 inch valve.
1 inch
Rc 1 port, tapered thread
- Orifice
- 25 mm
- Flow factor
- Cv 12
- Coil power at 24 V DC
- 18 W
- Weight
- 1.17 to 1.18 kg
The bar shows the flow factor against Cv 48, the 2 inch valve.
1 1/4 inch
G 1 1/4 port, parallel thread
- Orifice
- 35 mm
- Flow factor
- Cv 24
- Coil power at 24 V DC
- 50 W with a fixed lead, 48 W with a DIN plug
- Weight
- 2.23 to 2.44 kg
The bar shows the flow factor against Cv 48, the 2 inch valve.
1 1/2 inch
G 1 1/2 port, parallel thread
- Orifice
- 40 mm
- Flow factor
- Cv 29
- Coil power at 24 V DC
- 50 W with a fixed lead, 48 W with a DIN plug
- Weight
- 2.49 to 2.64 kg
The bar shows the flow factor against Cv 48, the 2 inch valve.
2 inch
G 2 port, parallel thread
- Orifice
- 50 mm
- Flow factor
- Cv 48
- Coil power at 24 V DC
- 50 W with a fixed lead, 48 W with a DIN plug
- Weight
- 3.73 to 3.96 kg
The bar shows the flow factor against Cv 48, the 2 inch valve.
Compare all seven sizes in one table
| Size | Port | Orifice | Flow factor | Coil at 24 V DC | Weight |
|---|---|---|---|---|---|
| 3/8 inch | Rc 3/8 | 16 mm | Cv 4.8 | 18 W | 0.88 to 0.91 kg |
| 1/2 inch | Rc 1/2 | 16 mm | Cv 4.8 | 18 W | 0.88 kg |
| 3/4 inch | Rc 3/4 | 20 mm | Cv 7.6 | 18 W | 0.90 to 0.91 kg |
| 1 inch | Rc 1 | 25 mm | Cv 12 | 18 W | 1.17 to 1.18 kg |
| 1 1/4 inch | G 1 1/4 | 35 mm | Cv 24 | 50 W or 48 W | 2.23 to 2.44 kg |
| 1 1/2 inch | G 1 1/2 | 40 mm | Cv 29 | 50 W or 48 W | 2.49 to 2.64 kg |
| 2 inch | G 2 | 50 mm | Cv 48 | 50 W or 48 W | 3.73 to 3.96 kg |
Rc ports have a tapered thread and G ports a parallel thread. On the three largest sizes the 24 V DC coil is 50 W with a fixed lead or 48 W with a DIN plug, and the weight range covers both connections.
Wiring
It is wired to the controller, so it closes without the network.
The coil is switched by the relay output of an AQUAIOT controller. The rule that closes the valve runs on the controller itself, so a wet sensor shuts the supply even when the radio link is down. The network only carries the alert and the record.
On site, no network needed
-
A wired sensor gets wet.
The sensor is wired to one of the controller’s inputs, so no radio link is involved.
-
The controller’s rule runs.
The rule is stored on the controller and runs on site.
-
The relay closes the valve.
The relay cuts the power to the coil, and the normally closed valve shuts.
Then, over the network
-
The alert goes out.
The controller reports the event over LoRaWAN or 4G.
Usual choice
24 V DC coil
Switched through the controller’s relay from a 24 V supply. 18 W draws 0.75 A and 50 W about 2.1 A, both inside the relay’s 3 A rating.
Mains coils
110 V AC or 220 V AC
For sites that would rather switch mains voltage. An electrician wires these to the relay, which is rated 3 A at 250 V AC.
Connection
DIN plug or fixed lead
A DIN terminal plug for easy replacement, or a grommet with a fixed lead for tight spaces.
Applications
It closes the supplies where a leak would run longest.
- Process water branches in plant rooms
- Process water to washers and rinsers
- Make-up water to chillers and coolers
- Wash-down and cleaning stations
- Irrigation lines
- Process supplies in unmanned kiosks and outbuildings
It is not for drinking-water supplies. The valve is not WRAS listed, so it is for process water, cooling water, wash-down and irrigation.
Installation
An engineer fits it in four steps.
AQUAIOT surveys the supply first: pipe size and thread, pressure, the branch that should close and where the controller and sensors go. A qualified engineer then fits the valve and wires it, and the system is tested before handover.
-
Isolate the branch.
Close the supply to the branch and drain it, so the valve can be fitted dry.
-
Fit the valve in line.
Fit it the right way round for the flow, on the branch that feeds the area you want to protect.
-
Wire the coil to the relay.
The coil goes to the controller’s relay output, and the leak sensors to its inputs.
-
Test the shut-off.
Wet a sensor, check the valve closes and the alert arrives, then reset the supply.
- Survey before ordering
- Fitted by an engineer
- Tested before handover
- Supported after go-live
Specifications
These are the full technical specifications.
Taken from the manufacturer’s data. Specifications are set by the manufacturer and may change without notice.
| Type | 2/2-way solenoid valve, direct diaphragm (high flow) |
|---|---|
| Action | Normally closed; normally open made to order |
| Port sizes | Rc 3/8, Rc 1/2, Rc 3/4, Rc 1, G 1 1/4, G 1 1/2, G 2 |
| Orifice | 16 mm to 50 mm, by size |
| Flow factor | Cv 4.8 to 48, by size |
| Suitable for | Water, air and light oil |
|---|---|
| Water pressure | 0 to 5 bar (0 to 500 kPa) |
| Air pressure | 0 to 7 bar (0 to 700 kPa) |
| Circulating oil | 0 to 5 bar (0 to 500 kPa) |
| Fluid and ambient temperature | −5 °C to +80 °C |
| Not suitable for | High-temperature liquids, liquids that set solid as they cool, corrosive fluids, viscosity above 20 cSt |
| Coil voltages | 24 V DC, 110 V AC, 220 V AC |
|---|---|
| Coil power at 24 V DC | 18 W on 3/8 to 1 inch; 50 W with a fixed lead or 48 W with a DIN plug on 1 1/4 to 2 inch |
| Minimum energising time | 0.05 s |
| Connection | DIN terminal plug or grommet with fixed lead |
| Body | Forged brass |
|---|---|
| Diaphragm | NBR, Viton or silicone |
| Spring | Stainless steel |
| Weight | 0.88 kg to 3.96 kg, by size and connection |
| Drinking water | Not WRAS listedFor process water, cooling water, wash-down and irrigation |
|---|
Questions
These are the technical questions we hear most.
Would you rather talk it through with an engineer?
Call 023 9223 3611 or email info@aquaiot.co.uk.
Can this valve go on a drinking-water supply?
No. Fittings on a drinking-water supply have to meet the Water Supply (Water Fittings) Regulations 1999, and this valve is not WRAS listed. It is for process water, cooling water, wash-down and irrigation.
Which size do I need?
The size that matches the thread on the pipe or fitting it goes on, from 3/8 inch to 2 inch. AQUAIOT confirms the size, the thread and the pressure at the survey, before anything is ordered.
Does it need a minimum water pressure to work?
No. It is a direct-acting diaphragm valve rated for water from 0 to 5 bar, so it opens and closes on gravity-fed supplies as well as pressurised lines up to 5 bar.
What happens if the power is lost?
The standard valve is normally closed, so it closes when power is lost. A normally open version, which stays open without power and closes on command, is made to order.
Which liquids should it not be used on?
The manufacturer rules out high-temperature liquids, liquids that set solid as they cool, corrosive fluids and fluids thicker than 20 cSt.
How is it wired?
Through the relay output of an AQUAIOT controller. The 24 V DC coil is the usual choice; 110 V AC and 220 V AC coils are also available, with a DIN plug or a fixed lead.
See how the whole shut-off system works.
AQUAIOT plans and fits the valve, the leak sensors and the controller that closes it as one system, and quotes them together as the leak shut-off kit.