Part G Water Efficiency: The 125 Litre Limit, the Proposed 105, and What Builders Should Do Now

TL;DR: Part G water efficiency sets the water use limit for new homes in England. Regulation 36 allows 125 litres per person per day, and a planning condition can require a stricter 110. Defra consulted until 16 December 2025 on cutting the mandatory figure to 105 and the optional one to 100, intending to implement in 2026 subject to the outcome and parliamentary approval, with a six-month transition. Design calculations can overstate performance, because some new homes use up to 195 litres a day, so measuring water use after handover is how a builder shows the homes work as designed.

Last updated: 19 October 2026

Key takeaways

  • Part G water efficiency means the Building Regulations requirement that new homes in England are designed so that estimated water use does not exceed 125 litres per person per day, set by Regulation 36.
  • A stricter 110 litres per person per day applies only where the planning permission requires it, which local planning authorities can do through their Local Plans.
  • Defra consulted until 16 December 2025 on cutting the mandatory figure from 125 to 105 and the optional one from 110 to 100, with a six-month transition, intending to implement in 2026 subject to the outcome and parliamentary approval.
  • Compliance is shown with a fittings-based approach or a water efficiency calculator, and checked by Building Control.
  • Actual use can be far higher than design: the consultation notes some new homes use up to 195 litres per person per day.
  • Metering and leak checks after handover show whether a development meets its design figure in use, and rainwater harvesting and reuse count in the calculation when specified.
Part G water efficiency in litres per person per day: actual use in some new homes up to 195, the mandatory limit 125, the optional standard 110, and the proposed 105 and 100
Design limits are well below what some new homes actually use.

A housebuilder specifies low-flow taps, a six-litre cistern and a bath that is smaller than average, runs the calculator, and gets the number under 125. The homes are built and sold. A year later, nobody can say whether the people living in them actually use 125 litres a day, or 195.

That gap is the real subject of Part G water efficiency in 2026. The rules are about to tighten, the calculation is a design estimate, and the evidence that a development works is measured use. This guide explains the current limit, the proposed change, how compliance is shown, what planners can require, and how to prove performance after handover.

What is Part G water efficiency?

Part G water efficiency is the part of the Building Regulations in England that limits the estimated water use of new homes. Regulation 36 sets a default of 125 litres per person per day, and Approved Document G gives the guidance for showing compliance, either with a fittings-based approach or with a calculation. Building Control checks that the homes meet it.

According to GOV.UK, Approved Document G covers the standards for cold water supply, water efficiency, hot water supply and systems, among other topics, and its latest version incorporates amendments listed on 1 October 2024. The water efficiency requirement is the one that sets the litres per person per day figure.

Two things are worth noting. First, the figure is an estimate calculated at design stage, not a measurement of what residents use. Second, it applies per person, using an assumed occupancy based on the number of bedrooms, so a bigger home is allowed more total water.

What is the current limit, and what is the 110 litre standard?

The default for new dwellings in England is 125 litres per person per day under Regulation 36. A tighter figure of 110 litres per person per day, the optional technical standard, applies only where the planning permission says so. A local planning authority can require it through its Local Plan, typically in areas under water stress.

The planning route matters. A builder working in an area with a local water policy may be designing to 110 or tighter, and the figure will be written in the planning decision notice. Some authorities already set tighter standards than the national ones. Always check the planning conditions as well as the Building Regulations.

How is Part G water efficiency shown in a design?

There are two routes. The fittings-based approach sets maximum flow rates for items such as showerheads, taps and toilets, and a home that uses only compliant fittings is accepted without a full calculation. The water efficiency calculator estimates daily use from the fittings, and is used where the fittings exceed the stated limits or where other items affect use.

How compliance is shown for the water efficiency requirement: design the fittings, use the fittings approach or the calculator, Building Control approval, optional standard through the planning condition, and completion
Compliance is a design check, signed off by Building Control.

The calculation also accounts for water-saving systems. Approved Document G says that where a shower is not provided, or a waste disposal unit, water softener or water re-use is proposed, the estimate must be worked out with the calculation method. Rainwater harvesting and greywater reuse can therefore reduce the estimate, but only if the system is specified, installed and, ideally, shown to work.

Our guide to rainwater harvesting for new builds covers how those systems are sized, and the Smart Water Butt shows how rainwater storage can be monitored and controlled.

What has Defra proposed for Part G?

Defra has proposed cutting the mandatory minimum from 125 to 105 litres per person per day, and the optional technical standard from 110 to 100, for areas of water stress or other local need. The consultation closed on 16 December 2025, with implementation intended in 2026 subject to the outcome and parliamentary approval, followed by a six-month transition.

These details come from the Chartered Institute of Housing briefing on the consultation. It also says both the fittings approach and the calculator would be revised to reflect changes in water use and technology, that the changes are expected to coincide with Part L updates and the Planning and Infrastructure Bill, and that the consultation flagged risks of higher costs and supply-chain delays if manufacturers cannot meet new limits in time.

Water UK reported in August 2026 that it supports moving the baseline from 125 to 105 and argues that one national standard gives more certainty to developers, manufacturers and water companies, as Water Magazine reported. That is an industry view, not a government decision. At the time of writing I could not find a published government response, so check GOV.UK for the current position before fixing a specification.

The water efficiency limits today and as proposed: mandatory 125 now and 105 proposed, optional 110 now and 100 proposed, with the consultation closing on 16 December 2025 and a six-month transition
Today’s limits, and the ones Defra proposed.

What should builders and planners do now?

Design to the proposed figure where you can, because homes designed today will be sold under whatever applies at completion, and a specification that already meets 105 will not need rework. Practical steps:

  1. Check the planning conditions. Look for a local optional standard of 110, 100 or tighter in the Local Plan and the decision notice.
  2. Specify to 105 where it costs little. Flow-limited showerheads and taps, and efficient toilets, usually cost little more than standard ones, though the consultation notes fittings can cost more.
  3. Run the calculation early. Do not leave it for the Building Control submission, when changing a bath or a shower is expensive.
  4. Price water reuse honestly. Rainwater harvesting and greywater reuse can lower the figure, but need maintenance and a plan for who looks after them.
  5. Plan the evidence. Decide now whether you will meter and verify, so the pipework allows for it.
  6. Watch the timetable. Implementation is intended in 2026 with a six-month transition, so a site starting now may complete under the new figure.

Why do new homes use more water than the design says?

New homes use more than the design figure because the design is an estimate from fittings, while real use depends on people, leaks and what is installed. The consultation notes that actual use in some new homes reaches up to 195 litres per person per day, far above the minimums, and suggests this may reflect varied water use or homes not being built to the current standard.

Proving water efficiency after handover: design estimate, handover leak check, sub-meter or smart meter, compare monthly use with design, then investigate and fix
The design number is the start of the evidence, not the end.

Four things commonly open the gap:

  • Fittings swapped after handover, for example a powerful shower head fitted by an occupant.
  • Hidden leaks, such as a toilet that runs on, which can use more than the whole design allowance without anyone noticing.
  • Different occupancy, because the calculation assumes a number of people per bedroom that may not match the household.
  • Rainwater or reuse systems that are not working, so the saving in the calculation never appears.

How can monitoring prove that a development performs?

Monitoring proves performance by measuring what the homes actually use. A sub-meter or smart meter on each home or block gives a daily figure to compare with the design number, and continuous flow monitoring flags leaks that a monthly read would miss. Data from a handful of homes in a development shows whether the specification works before the next phase is built.

The consultation’s call for evidence also asked about smarter leak detection measures and about rainwater and greywater reuse, which signals where policy may go next. For a developer or housing association, the practical value is simple: if the figure is measured and below design, it supports sales, planning conditions and any future funding or reporting. If it is above design, you learn why while the homes are still under warranty.

A practical way to start is small: choose a few homes or one block in the first phase, fit meters and read them from handover, and compare the first three months with the design figure. The cost is modest next to a development, and the result tells you whether to change the specification before the remaining homes are built.

Our guides to water sub-metering, water demand management and leak detection return on investment explain the options, and the SuDS standards guide covers the drainage side of new development.

Who needs to act on the Part G changes?

Several roles share the work, and the proposed change touches each of them differently.

  • Housebuilders and developers choose the fittings and carry the cost, so they need the specification settled before the next phase is priced.
  • Architects and mechanical and electrical designers run the calculation and should do it at concept stage, not at submission.
  • Planners and local planning authorities decide whether a Local Plan requires the optional standard, and word the condition.
  • Building Control bodies check the estimate during and after construction.
  • Housing associations and landlords inherit the running costs of water and hot water, so lower use helps tenants directly.
  • Water companies use new-home standards in their demand forecasts, which is why Water UK has taken a position.

What belongs in a water efficiency handover pack?

A handover pack turns a design promise into something the occupant and the owner can use. A useful pack for each home includes:

  1. The final calculation or fittings schedule, with the model numbers of the installed taps, showers and toilets.
  2. The location of the stopcock, any sub-meter and any isolation valves.
  3. A simple note on the water-saving features and why they matter, such as flow limiters.
  4. For rainwater or reuse systems, the maintenance schedule and a contact.
  5. A statement that replacing fittings with higher-flow ones may break the design assumption.

If you plan to monitor, add the meter reading at handover as the baseline, so the first months of data have a starting point.

How does Part G relate to nutrient neutrality?

Part G sets how much water a new home is designed to use. Some areas also apply separate planning constraints that depend on the water or nutrients a development adds, which is why a tight local water standard often appears in Local Plans for those areas. Lower use in the home can help meet those constraints, but the rules and offsetting methods differ by area. Our guide to nutrient neutrality monitoring explains how monitoring supports one of them.

What mistakes do teams make with Part G?

  • Treating the calculation as the finish line. It is a design estimate. Actual use is what residents pay for and what regulators and water companies increasingly look at.
  • Ignoring the planning condition. The Local Plan may set 110 or 100 before the national figure changes.
  • Forgetting that reuse needs upkeep. A harvesting tank with no maintenance contract stops delivering its saving.
  • Leaving metering until later. Pipework laid without a meter point costs far more to alter than to plan.
  • Assuming the proposal is law. The proposed 105 and 100 figures are proposals until implemented, so confirm the status on GOV.UK.

Frequently asked questions

What is Part G of the Building Regulations?

Part G covers sanitation, hot water safety and water efficiency. Its water efficiency requirement limits the estimated water use of new homes in England to 125 litres per person per day, unless a planning condition requires a lower figure.

What is the water efficiency limit for new homes in England?

The default is 125 litres per person per day under Regulation 36. An optional technical standard of 110 litres per person per day applies where the planning permission requires it.

Is the Part G limit changing to 105 litres?

Defra has proposed it. The consultation closed on 16 December 2025 and proposed 105 litres per person per day as the mandatory figure and 100 as the optional standard, with implementation intended in 2026 subject to the outcome and parliamentary approval. Check GOV.UK for the current status.

How do you prove Part G compliance?

At design stage, use the fittings-based approach or the water efficiency calculator, and have Building Control approve it. Compliance is a design estimate, so metering after handover is how you show real performance.

Do rainwater harvesting and greywater count under Part G?

Yes, where a re-use system is proposed the estimate is calculated using the calculation method, so a specified and working system can reduce the figure. It must be installed and maintained for the saving to be real.

Why do some new homes use more water than the limit?

The limit is a design estimate. Real use varies with occupants, fittings changed after handover and leaks, and the consultation notes that some new homes use up to 195 litres per person per day.

Where to start

If you are planning a development, check the planning condition, run the calculation early and decide whether to meter. Contact AQUAIOT with the number of homes and the water systems you plan, and we will suggest how to monitor use, leaks and rainwater storage so you can show the design works.