Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611
Leak detection for student accommodation

Catch the summer leak while the halls are standing empty.

Moisture, flow and freeze monitoring with automatic shut-off across cluster flats, en-suites, kitchens and risers. AQUAIOT catches the leak that starts in an empty block over the summer before it floods a floor and delays the September intake.

Live monitoring. Automatic shut-off.
AQUAIOT Leak Dashboard
38Sensors OK
2Caution
1Isolated
Plant room – moistureDryOK
Riser 3 – flow14.8 L/minIsolated
Roof tank – temp4.2°CFreeze risk
Incoming main – flowNormalOK
Blocks empty over summer leak unwatched.Long vacation breaks leave whole blocks unoccupied for months. A leak that starts the day students move out can run until the next intake arrives to a flooded floor.
High density multiplies the points of failure.Dozens of en-suites and shared kitchens per block mean far more joints, valves and seals than a normal residential building, and far more places a leak can begin.
High turnover means nobody reports early.Residents change every year and rarely flag a slow weep behind a unit. By the time staining shows in a corridor the damage is already done.
A flooded floor delays the intake.Escape of water in a hall can take rooms out of use just as new tenancies start, forcing reallocation, refunds and reputational damage in clearing season.
The AQUAIOT Solution

Leak detection for high-density blocks that empty over summer

Purpose-built student accommodation packs dozens of bathrooms and kitchens into each block, then sits empty for months over the summer when an unwatched leak does the most damage. AQUAIOT senses moisture across en-suites, kitchens and risers, watches flow on each block from one dashboard, and isolates the supply automatically during the void so a vacation leak does not greet the new intake in September.

Cover every en-suite and kitchen on the block. Moisture sensors in cluster-flat bathrooms, shared kitchens and airing cupboards, with flow analytics on block supplies, all visible on one accommodation dashboard.
Shut off automatically over the summer void. Auto-isolation valves close supplies in blocks that empty between tenancies, so a leak in a vacant flat cannot run for weeks unnoticed.
Route alarms past a high turnover of residents. Role-based escalation sends each alert to the duty maintenance team and warden by SMS, email and app, not to residents who change every year.
Request a Consultation
Live leak status
Incoming main – flow0.4 L/min
Night-line flow – Zone A0.0 L/min
Plant room – moistureDry
Riser 3 – flow14.8 L/min
Auto-isolation valve closed – Riser 3
Abnormal flow detected 03:14. Supply isolated, team notified.
How It Works

Three steps from first drop to evidence

Step 01

Detect

AQUAIOT moisture, flow and freeze sensors are deployed at the points water escapes. Every reading is timestamped and logged to the cloud over secure cellular or LoRaWAN telemetry.

Step 02

Alert and isolate

When moisture is sensed or flow goes abnormal, AQUAIOT raises an immediate alert by SMS, email and app, and closes the auto-isolation valve so water is stopped before damage spreads.

Step 03

Record

Every reading, alert and isolation event is captured in exportable, timestamped logs that integrate with CAFM and BMS, so evidence for insurers is ready on demand.

Capabilities

Everything a leak detection programme needs

Purpose-built for estates, facilities and risk teams protecting buildings against escape of water across single or multiple sites.

Moisture sensing at the risk points

Point, rope and tray sensors detect water at first contact under appliances, in plant rooms, risers and tank rooms, before it spreads.

Inline flow analytics

Continuous flow monitoring on the incoming main learns normal use and flags the slow weep or continuous draw a manual check never sees.

Freeze protection

Temperature monitoring on exposed and loft pipework warns before a freeze leads to a burst, so action can be taken in time.

Automatic shut-off

Auto-isolation valves close the supply the moment a moisture or abnormal-flow threshold is crossed, with manual remote override for the duty holder.

Multi-channel alerts with escalation

SMS, email and app alerts with role-based routing, so the right person responds day or night, on a single site or across a portfolio.

Open integration, no lock-in

Connects to BMS, CAFM and SCADA via RS485/Modbus or REST API, with audit-ready exportable records for insurers and owners.

Evidence & Assurance

Evidence for your insurers and auditors.

Audit-ready event logs Summer-void auto shut-off Role-based escalation Secure cellular and LoRaWAN telemetry
Book a Demo

No commitment. Talk to our engineering team.

Open, interoperable systems. No lock-in. Engineered for operational environments.
Cellular + LoRaWAN telemetry Encrypted payloads & OTA updates RS485/Modbus + REST API Role-based cloud dashboards CAFM / BMS compatible
Questions & Answers

Common questions

How does AQUAIOT protect student blocks over the summer?
Auto-isolation valves close supplies in blocks that empty between tenancies, so a leak in a vacant flat cannot run for the whole vacation. The estates team is alerted the moment abnormal flow or moisture is detected.
Where are sensors placed in student accommodation?
Moisture sensors sit in cluster-flat en-suites, shared kitchens, airing cupboards and riser cupboards, with freeze protection on exposed runs. Inline flow analytics watch each block supply for slow losses.
Can the system shut the water off by itself?
Yes. Auto-isolation valves close the supply on a moisture or abnormal-flow event, before water reaches the floors below, with an immediate alert to the duty maintenance team and warden.
How are alarms routed when residents change every year?
Role-based routing sends each alarm to the responsible maintenance team, warden or out-of-hours contractor by SMS, email and app, so the right staff respond without relying on residents to report a problem.
Will fitting sensors disrupt occupied flats?
No. Moisture sensors and clamp-on flow monitoring are non-invasive and retrofit-friendly, so most work can happen during the summer void with no pipe cutting and minimal time in any flat.
Ready when you are

Protect the halls through every vacation. Talk to an engineer.

Tell us about your blocks, flat layout and vacation pattern, and we will scope leak detection and automatic shut-off for your accommodation.

Student accommodation leak detection – Speak to an AQUAIOT engineer about your buildings.
Speak to an Expert
Shopping Cart (0 items)