Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611
Leak detection guide

How water moisture sensors work, and where to put them.

Water moisture sensors are the front line of leak detection, but only if they sit where water actually goes. This guide explains how they sense water, the difference between point and rope sensors, and the right places to deploy them.

Live monitoring. Automatic shut-off.
AQUAIOT Leak Dashboard
38Sensors OK
2Caution
1Isolated
Plant room – moistureDryOK
Riser 3 – flow14.8 L/minIsolated
Roof tank – temp4.2°CFreeze risk
Incoming main – flowNormalOK
A misplaced sensor is a dry sensor.The most common mistake is mounting a moisture sensor where water never reaches, so it reads dry while a leak runs to a low point somewhere else entirely.
Point and rope are not interchangeable.A point sensor watches one spot and a rope sensor watches a whole line, so using the wrong type leaves either gaps along a run or wasted coverage at a single point.
Floor sensors catch water late.A moisture sensor only triggers once water has reached it, so on its own it misses the weep still inside the pipe, which is why flow analytics work alongside it.
Follow gravity, not convenience.Water travels to the lowest accessible point, so sensors belong where water will collect first rather than where they are easiest to reach and wire.
The AQUAIOT Solution

How they sense, and where they belong

A water moisture sensor detects the presence of water by a change it can measure, most commonly the drop in electrical resistance when water bridges two contacts, so a dry sensor reads open and a wet one reads closed and raises an alert. There are two main forms. Point sensors sit at a single spot, ideal under an appliance, beside a tank or at the low point of a plant room floor where water collects. Rope or cable sensors run as a line along a pipe route, a riser or a perimeter, detecting water anywhere along their length, which suits long runs where a leak could appear at any point. Placement is everything, a sensor in the wrong spot stays dry while water tracks elsewhere. The rule is to follow gravity and put sensors where water will pool first. AQUAIOT pairs moisture sensors with inline flow analytics so a leak still inside the pipe is caught before it ever reaches the floor.

They sense water by resistance. Most moisture sensors detect the drop in electrical resistance when water bridges their contacts, switching from a dry open state to a wet state that raises an alert.
Point and rope suit different jobs. Point sensors cover a single spot under an appliance or at a floor low point, while rope sensors run along a pipe route or perimeter to catch water anywhere on the line.
Placement decides whether they work. Sensors must follow gravity and sit where water pools first, because a sensor in the wrong spot stays dry while the leak tracks away from it.
Request a Consultation
Live leak status
Incoming main – flow0.4 L/min
Night-line flow – Zone A0.0 L/min
Plant room – moistureDry
Riser 3 – flow14.8 L/min
Auto-isolation valve closed – Riser 3
Abnormal flow detected 03:14. Supply isolated, team notified.
How It Works

Three steps from first drop to evidence

Step 01

Detect

AQUAIOT moisture, flow and freeze sensors are deployed at the points water escapes. Every reading is timestamped and logged to the cloud over secure cellular or LoRaWAN telemetry.

Step 02

Alert and isolate

When moisture is sensed or flow goes abnormal, AQUAIOT raises an immediate alert by SMS, email and app, and closes the auto-isolation valve so water is stopped before damage spreads.

Step 03

Record

Every reading, alert and isolation event is captured in exportable, timestamped logs that integrate with CAFM and BMS, so evidence for insurers is ready on demand.

Capabilities

Everything a leak detection programme needs

Purpose-built for estates, facilities and risk teams protecting buildings against escape of water across single or multiple sites.

Moisture sensing at the risk points

Point, rope and tray sensors detect water at first contact under appliances, in plant rooms, risers and tank rooms, before it spreads.

Inline flow analytics

Continuous flow monitoring on the incoming main learns normal use and flags the slow weep or continuous draw a manual check never sees.

Freeze protection

Temperature monitoring on exposed and loft pipework warns before a freeze leads to a burst, so action can be taken in time.

Automatic shut-off

Auto-isolation valves close the supply the moment a moisture or abnormal-flow threshold is crossed, with manual remote override for the duty holder.

Multi-channel alerts with escalation

SMS, email and app alerts with role-based routing, so the right person responds day or night, on a single site or across a portfolio.

Open integration, no lock-in

Connects to BMS, CAFM and SCADA via RS485/Modbus or REST API, with audit-ready exportable records for insurers and owners.

Evidence & Assurance

Evidence for your insurers and auditors.

Point and rope sensing Moisture and flow sensing Role-based escalation Audit-ready event logs
Book a Demo

No commitment. Talk to our engineering team.

Open, interoperable systems. No lock-in. Engineered for operational environments.
Cellular + LoRaWAN telemetry Encrypted payloads & OTA updates RS485/Modbus + REST API Role-based cloud dashboards CAFM / BMS compatible
Questions & Answers

Common questions

How do water moisture sensors work?
Most detect the drop in electrical resistance when water bridges two contacts, switching from a dry open state to a wet state that raises an alert to the responsible person.
What is the difference between point and rope sensors?
A point sensor watches a single spot, such as under an appliance, while a rope or cable sensor runs along a pipe route or perimeter and detects water anywhere on its length.
Where should moisture sensors be placed?
Follow gravity and put them where water pools first, under appliances, beside tanks, at plant room floor low points and along risers, not where they are simply easiest to fit.
Do moisture sensors catch every leak?
On their own, no. A moisture sensor only triggers once water reaches it, so flow analytics work alongside to catch the slow weep while it is still inside the pipe.
Are the sensors hard to install?
No. Moisture sensors are non-invasive and retrofit-friendly, fitted at the points water collects without cutting into pipes or shutting the building down.
Ready when you are

Place sensors where water goes. Talk to an engineer.

Tell us about your appliances, tanks, plant rooms and risers, and we will explain which moisture sensors belong where to catch a leak at its first pooling point.

Moisture sensors – Speak to an AQUAIOT engineer about your buildings.
Speak to an Expert
Shopping Cart (0 items)