Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611

Fatberg prevention: how monitoring catches FOG blockages before they surcharge

TL;DR. Fatberg prevention starts long before a 130-tonne mass shuts a sewer. It starts at the slow-draining kitchen drain, where fat, oil, grease and wet wipes congeal into the blockages that surcharge a network. This data-story unpacks the numbers behind FOG blockage monitoring and shows how a radar level sensor on a wet well or manhole sees the level rising and alerts before a spill. The cheapest fatberg prevention is catching the surcharge before it tops the threshold.

Last updated: 2 July 2026

Key takeaways

  • The 2017 Whitechapel fatberg weighed over 130 tonnes and stretched about 250 metres, built from fat, oil, grease and wet wipes.
  • UK water companies clear an estimated 300,000 sewer blockages a year, mostly caused by fats, oils, grease and wipes.
  • Serious pollution incidents from England’s water companies rose about 60% to 75 in 2024, per the Environment Agency.
  • Fatberg prevention is a monitoring problem: a blockage restricts flow, the level rises upstream, and a threshold is crossed.
  • The AQUAIOT Radar level sensor watches a wet well or manhole non-contact through vapour and raises an alert before a surcharge spills.
AQUAIOT fatberg prevention hook slide showing that a 130-tonne fatberg starts as a slow-draining kitchen drain.
A 130-tonne fatberg once shut a London sewer. Yours starts as a slow-draining kitchen drain.

What is fatberg prevention and why does it matter?

Fatberg prevention is the practice of stopping the fat, oil, grease and wet wipes that congeal in a sewer from ever building into a flow-blocking mass, and monitoring the network so an early blockage is caught before it surcharges. A fatberg does not appear overnight. It begins as a film of cooking fat and wipes on a pipe wall, thickens over weeks, and only becomes a headline when it fills the bore. The most famous example makes the scale plain.

The 2017 Whitechapel fatberg weighed over 130 tonnes and stretched about 250 metres, a congealed mass of fat, oil, grease and wet wipes in a Victorian London sewer. That is a spectacular failure at the end of a very ordinary process. Every canteen, kitchen and washroom pours the same ingredients into the same pipes, and on your own site it starts at the slow-draining drain no one flags until it backs up.

It matters because the failure mode is expensive and dirty, and that cost is the whole case for fatberg prevention. A blocked sewer does not just stop; it surcharges, backing raw wastewater up into buildings or out through a combined sewer overflow into a watercourse. That is a pollution event, a clean-up bill and, for the operator, a reportable incident. Getting ahead of it is cheaper than clearing it.

What do the fatberg numbers actually tell us?

The numbers tell us that fatbergs are not freak events but the visible tip of a routine, nationwide blockage problem, and that fatberg prevention is a scale problem as much as a site one. UK water companies clear an estimated 300,000 sewer blockages a year, most of them caused by fats, oils, grease and wipes rather than anything structural. That is an industry estimate, not a single audited figure, but the order of magnitude is the point: blockages are constant, and each one is a surcharge waiting to happen.

Slope infographic showing how a FOG blockage restricts flow so the wet well level rises to the surcharge threshold, the mechanism behind fatberg prevention.
A blockage restricts flow, the level climbs, and a surcharge threshold is crossed.

The consequence shows up in the pollution record.

Serious pollution incidents from England’s water companies rose about 60% to 75 in 2024, according to the Environment Agency.
Not every one is a fatberg, but blockages that surcharge into rivers are a recognised contributor. For context, in 2025 there were 291,492 monitored storm-overflow spills, down 35% year on year. Better visibility turns a blockage from a surprise into a signal.

How does FOG blockage monitoring catch a fatberg early?

FOG blockage monitoring turns fatberg prevention into something you can measure, by watching what a growing blockage does to the water, not the grease. You cannot easily see fat building on a pipe wall from the surface, but you can measure its effect: as a blockage narrows the bore, flow slows and the water level upstream rises. Put a level sensor on the wet wells, manholes and rising mains where surcharge shows first, and a slow climb toward the threshold becomes an early warning.

This is the shift from reactive to proactive that fatberg prevention and sewer blockage prevention both need. The reactive model waits for a report: a backed-up gully, a flooded basement, a pollution call-out. The proactive model watches wet well surcharge monitoring data continuously and flags a rising trend or a rate-of-rise anomaly before the overflow. It starts upstream of the sewer entirely: bin it dont flush it, so the fat oil and grease drains never carry what forms a fatberg. Our guide to sewer blockage detection with IoT covers the detection logic, and the pumping station monitoring guide looks at the wet wells where surcharge is caught.

How does a radar level sensor spot a surcharge before a spill?

A radar level sensor spots a surcharge by measuring the distance to the water surface non-contact, from above, and turning a rising level into a timed alert before it reaches the overflow, which is fatberg prevention in practice. Because it never touches the effluent, a fatberg forming below cannot foul it, and it keeps reading through the foam, vapour and condensation that defeat float switches. The level trend is the tell: when a blockage is building, the baseline creeps up, and the sensor sees it long before a human would.

The AQUAIOT Radar level sensor mounted in a manhole, reading wet well level non-contact through vapour for fatberg prevention.
Non-contact radar reads the wet well through vapour, so a surcharge is seen early.

The AQUAIOT Radar Smart Water Level Monitoring sensor is built for exactly this duty. It uses 60 GHz mmWave radar for non-contact level sensing accurate to within about 2 mm, penetrates foam, vapour and condensation, and works reliably in enclosed underground chambers, with ATEX variants for hazardous atmospheres. Deployed across a network as a fatberg prevention layer, it turns wet wells, manholes and rising mains into a monitored line of defence, feeding the AQUAIOT Cloud, which raises threshold and rate-of-rise alerts by SMS, email and app the moment a level trends toward surcharge. It is one part of a wider sewer monitoring service that sits alongside the enforcement picture in our wastewater enforcement monitoring analysis.

Context stat-stack slide showing 75 serious pollution incidents up 60% and 291,492 monitored storm-overflow spills, the case for fatberg prevention monitoring.
The pollution and spill record is the case for catching a blockage before it surcharges.

Frequently asked questions

What causes a fatberg?

A fatberg is caused by fat, oil, grease and wet wipes congealing together in a sewer. Cooking fats poured down drains solidify on the pipe wall, wipes snag on them, and over weeks the mass grows until it blocks the bore. The 2017 Whitechapel fatberg, over 130 tonnes, is the extreme end of this everyday process.

How does monitoring help with fatberg prevention?

Monitoring helps fatberg prevention by measuring the water level a growing blockage pushes up, not the grease itself. As a fatberg narrows the pipe, flow slows and the upstream level rises, so a level sensor on a wet well or manhole detects the trend and alerts before a surcharge or spill. It turns an invisible build-up into an early, actionable signal.

Why is a radar level sensor used in sewers?

A radar level sensor is used in sewers because it measures level non-contact from above, so it is not fouled by effluent and keeps reading through foam, vapour and condensation. Those are exactly the conditions inside a wet well or manhole that defeat contact float switches, which makes radar the reliable choice for wet well surcharge monitoring and, in turn, for fatberg prevention.

What can I do to reduce blockages on my site?

The single most effective step is to keep fat, oil and grease out of the drains and to bin it dont flush it for wipes. Scrape plates, use grease traps in canteens, and never pour cooking fat down a sink. Pair that source control with level monitoring on your wet wells, and you have both halves of fatberg prevention, so any blockage that forms is caught before it surcharges.

AQUAIOT call-to-action slide inviting readers to see the surcharge before the spill with fatberg prevention monitoring at aquaiot.co.uk.
See the surcharge before the spill with AQUAIOT.

Fatberg prevention is not really about the 130-tonne monster in the tunnel; it is about the slow drain and the rising level long before that. Keep the fat, oil, grease and wipes out of the sewer, and watch the wet wells that surcharge first. If you want to see a blockage before it becomes a spill, talk to AQUAIOT about sewer monitoring built on the AQUAIOT Radar level sensor and the AQUAIOT Cloud.

By GP, Digital and IoT lead at AQUAIOT.

Previous Post
Newer Post
Shopping Cart (0 items)