Guest water safety,
monitored continuously.
Through every quiet season.
Wireless temperature sensors at tanks, loops, sentinel taps, amenity blocks, and pool and spa plant across the park, checking thresholds against HSE L8, HSG274, and HSG282 automatically, around the clock.
Continuous visibility.
Shoulder-season cover.
Defensible records.
AQUAIOT replaces manual rounds with continuous automated monitoring across accommodation, amenity blocks, and pool plant, so your L8 record stays current through peak season and long closures and is always ready for inspection.
Temperature above L8 calorifier threshold. Notification sent 14:32.
Three steps to continuous L8 compliance
Monitor
AQUAIOT sensors are deployed at tanks, loops, calorifiers, and sentinel outlets. Temperature is profiled continuously, every reading timestamped and logged to the cloud over secure cellular or LoRaWAN telemetry.
Alert
When temperatures drift outside HSE L8 thresholds, or when a scheduled flush is missed, AQUAIOT triggers an immediate alert via SMS, email, or app, with role-based escalation rules for your estates team.
Record
Every reading, alert, and action is captured in tamper-evident audit logs. Records are exportable on demand and integrate with CAFM, BMS, and AIMS systems, so audit preparation is minutes, not days.
Everything your L8 programme needs
Purpose-built for estates, facilities, and compliance teams managing water systems across single or multiple sites.
Real-time temperature profiling
Continuous monitoring at tanks, calorifiers, loops, and sentinel outlets. Every reading timestamped and stored, never a gap in your record.
HSE L8 threshold alerting
Thresholds checked against HSE L8 and ACoP guidance. Alerts fired immediately when cold water exceeds 20C or hot water falls below 50C at point of use.
Missed-flush detection
AQUAIOT detects when scheduled flushing routines are not completed and generates an automatic alert, so no event is undocumented.
Tamper-evident audit trails
Every reading and action is logged with a secure, unalterable timestamp. Exportable records ready for audit, inspection, or HSE enquiry at any time.
API / BMS / CAFM integration
Open and interoperable. AQUAIOT connects to your existing SCADA, AIMS, CAFM, and BMS platforms via RS485/Modbus or REST API, no lock-in.
Retrofit-friendly deployment
Non-invasive sensors designed for live environments. No pipe cutting, no shutdown. AQUAIOT engineers handle site survey, installation, and commissioning.
Aligned to the standards your auditors check.
No commitment. Talk to our engineering team.
Built for every kind of holiday park
Cover dispersed units through closures.
Caravan and lodge parks spread accommodation across a wide site where units sit closed through the off season and shoulder months. Manual rounds cannot reach every unit at the frequency stagnation risk demands.
- Continuous monitoring across caravans, lodges, and washblocks from one dashboard
- Automatic alerts when closed units develop risk in the shoulder season
- Documented evidence that water is safe before each unit reopens
- Profiling at tanks, loops, and sentinel outlets across the park
Shared facilities, watched continuously.
Glamping and camping sites concentrate water risk in shared amenity blocks, kitchens, and shower facilities that swing between heavy peak use and quiet closed periods. Continuous monitoring tracks that swing without manual rounds.
- Continuous profiling at shared shower, kitchen, and toilet blocks
- Alerts when seasonal low-use periods raise stagnation risk
- Tamper-evident records for the responsible person and inspectors
- Cellular and LoRaWAN telemetry for remote or rural sites
Every park, one dashboard.
Operator groups manage L8 duty of care across many parks with varied facilities and stretched local teams. Standardising manual monitoring across a portfolio of seasonal sites is operationally fragile and hard to evidence.
- Continuous monitoring across every park from a single dashboard
- Standardised records and alerts across the whole group
- Role-based access for group compliance leads and park managers
- Audit-ready evidence for environmental health, insurers, and head office
A live picture, not a clipboard.
Park facilities teams carry hands-on L8 responsibility across accommodation, amenity blocks, and pool plant while running everything else on site. A live monitoring picture replaces uncertainty between rounds with continuous assurance.
- Real-time visibility of water temperatures across the park
- Immediate notification when a flush is missed or a threshold breached
- Tamper-evident records that back up the written scheme of control
- Retrofit-friendly install with no shutdown of the water system
Legionella monitoring for holiday parks, answered
How does automated monitoring support our ACoP L8 duty across a holiday park?
How does it handle the closed season and shoulder months?
Can it cover swimming pools and spa pools as well?
Can it monitor dispersed caravans and lodges from one place?
Can sensors be fitted without disrupting guests?
How quickly can we produce records for an environmental health inspection?
Related AQUAIOT monitoring solutions
Stop leaving closed-season units uncovered.
Talk to our engineering team about continuous monitoring, shoulder-season cover, and audit-ready compliance records for your holiday park.

