Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611
Legionella Monitoring for Holiday Parks

Guest water safety,
monitored continuously.
Through every quiet season.

Wireless temperature sensors at tanks, loops, sentinel taps, amenity blocks, and pool and spa plant across the park, checking thresholds against HSE L8, HSG274, and HSG282 automatically, around the clock.

Live monitoring. Continuous compliance.
AQUAIOT L8 Dashboard
42Outlets OK
3Caution
1Alert
Tank A – Cold Feed18.4°COK
Outlet 7 – HWS Return49.1°CCaution
Outlet 12 – Sentinel56.8°CAlert
CW Tank B17.2°COK
Seasonal occupancy means seasonal stagnationCaravans, lodges, and amenity blocks sit empty through the closed season and shoulder months. Water stands in pipework for weeks and warms into the Legionella growth range before guests return.
Dispersed pitches outpace manual roundsHundreds of caravans, lodges, and washblocks spread across a large site cannot be covered by manual rounds at the frequency ACoP L8 expects. Coverage is slow and uneven.
Pools and spas raise the risk profileOn-park swimming pools and spa pools combine warmth and aerosol within their own HSG282 context, demanding closer water-safety attention than a periodic round can give.
Audit prep across a park eats timeWhen an environmental health officer, the HSE, or an insurer asks for temperature history, compiling records from scattered amenity blocks and accommodation takes the team days.
The AQUAIOT Solution

Continuous visibility.
Shoulder-season cover.
Defensible records.

AQUAIOT replaces manual rounds with continuous automated monitoring across accommodation, amenity blocks, and pool plant, so your L8 record stays current through peak season and long closures and is always ready for inspection.

Real-time temperature profiling at tanks, loops, sentinel outlets, amenity blocks, and pool and spa plant, continuous rather than periodic.
Threshold alerts against HSE L8, HSG274, and HSG282, immediate SMS, email, and app notification when a closed unit develops risk or a flush is missed in the shoulder season.
Tamper-evident, exportable audit trails, instant evidence for environmental health officers, insurers, and your written scheme of control.
Request a Consultation
Live Outlet Status
CW Tank – Return Temp16.8°C
HWS Flow – Calorifier60.4°C
HWS Return – Loop 349.3°C
Sentinel Outlet 1256.8°C
Alert triggered – Outlet 12
Temperature above L8 calorifier threshold. Notification sent 14:32.
How It Works

Three steps to continuous L8 compliance

Step 01

Monitor

AQUAIOT sensors are deployed at tanks, loops, calorifiers, and sentinel outlets. Temperature is profiled continuously, every reading timestamped and logged to the cloud over secure cellular or LoRaWAN telemetry.

Step 02

Alert

When temperatures drift outside HSE L8 thresholds, or when a scheduled flush is missed, AQUAIOT triggers an immediate alert via SMS, email, or app, with role-based escalation rules for your estates team.

Step 03

Record

Every reading, alert, and action is captured in tamper-evident audit logs. Records are exportable on demand and integrate with CAFM, BMS, and AIMS systems, so audit preparation is minutes, not days.

Capabilities

Everything your L8 programme needs

Purpose-built for estates, facilities, and compliance teams managing water systems across single or multiple sites.

Real-time temperature profiling

Continuous monitoring at tanks, calorifiers, loops, and sentinel outlets. Every reading timestamped and stored, never a gap in your record.

HSE L8 threshold alerting

Thresholds checked against HSE L8 and ACoP guidance. Alerts fired immediately when cold water exceeds 20C or hot water falls below 50C at point of use.

Missed-flush detection

AQUAIOT detects when scheduled flushing routines are not completed and generates an automatic alert, so no event is undocumented.

Tamper-evident audit trails

Every reading and action is logged with a secure, unalterable timestamp. Exportable records ready for audit, inspection, or HSE enquiry at any time.

API / BMS / CAFM integration

Open and interoperable. AQUAIOT connects to your existing SCADA, AIMS, CAFM, and BMS platforms via RS485/Modbus or REST API, no lock-in.

Retrofit-friendly deployment

Non-invasive sensors designed for live environments. No pipe cutting, no shutdown. AQUAIOT engineers handle site survey, installation, and commissioning.

Compliance & Standards

Aligned to the standards your auditors check.

ACoP L8 Holiday Duty HSG274 & HSG282 Pools Immutable Timestamped Logs Exportable Evidence
Book a Demo

No commitment. Talk to our engineering team.

Who It’s For

Built for every kind of holiday park

Caravan & Lodge Parks

Cover dispersed units through closures.

Caravan and lodge parks spread accommodation across a wide site where units sit closed through the off season and shoulder months. Manual rounds cannot reach every unit at the frequency stagnation risk demands.

  • Continuous monitoring across caravans, lodges, and washblocks from one dashboard
  • Automatic alerts when closed units develop risk in the shoulder season
  • Documented evidence that water is safe before each unit reopens
  • Profiling at tanks, loops, and sentinel outlets across the park
Glamping & Camping Sites

Shared facilities, watched continuously.

Glamping and camping sites concentrate water risk in shared amenity blocks, kitchens, and shower facilities that swing between heavy peak use and quiet closed periods. Continuous monitoring tracks that swing without manual rounds.

  • Continuous profiling at shared shower, kitchen, and toilet blocks
  • Alerts when seasonal low-use periods raise stagnation risk
  • Tamper-evident records for the responsible person and inspectors
  • Cellular and LoRaWAN telemetry for remote or rural sites
Park Operator Groups

Every park, one dashboard.

Operator groups manage L8 duty of care across many parks with varied facilities and stretched local teams. Standardising manual monitoring across a portfolio of seasonal sites is operationally fragile and hard to evidence.

  • Continuous monitoring across every park from a single dashboard
  • Standardised records and alerts across the whole group
  • Role-based access for group compliance leads and park managers
  • Audit-ready evidence for environmental health, insurers, and head office
On-Site Facilities Teams

A live picture, not a clipboard.

Park facilities teams carry hands-on L8 responsibility across accommodation, amenity blocks, and pool plant while running everything else on site. A live monitoring picture replaces uncertainty between rounds with continuous assurance.

  • Real-time visibility of water temperatures across the park
  • Immediate notification when a flush is missed or a threshold breached
  • Tamper-evident records that back up the written scheme of control
  • Retrofit-friendly install with no shutdown of the water system
Open, interoperable systems. No lock-in. Engineered for operational environments.
Cellular + LoRaWAN telemetry Encrypted payloads & OTA updates RS485/Modbus + REST API Role-based cloud dashboards CAFM / BMS compatible
Questions & Answers

Legionella monitoring for holiday parks, answered

How does automated monitoring support our ACoP L8 duty across a holiday park?
AQUAIOT records temperatures continuously at tanks, loops, sentinel outlets, and amenity blocks and checks them against HSE L8 guidance, supporting the holiday accommodation duty set out in the ACoP. It strengthens the duty holder’s written scheme of control with a complete, tamper-evident record, while responsibility for the overall control scheme remains with the operator.
How does it handle the closed season and shoulder months?
AQUAIOT keeps profiling temperatures continuously while units and amenity blocks are closed and sends immediate alerts if readings drift into risk zones or a planned flush is missed. That gives documented evidence that water is safe before each unit reopens for the season.
Can it cover swimming pools and spa pools as well?
Yes. AQUAIOT provides continuous temperature monitoring at pool and spa plant and associated outlets that supports L8 and HSG274 duties, sitting alongside the wider HSG282 spa pool considerations the operator manages as part of the overall control scheme.
Can it monitor dispersed caravans and lodges from one place?
Yes. Continuous monitoring across the whole park is visible from a single dashboard, with role-based access for park managers and group compliance leads, so coverage stays consistent without travelling to every unit.
Can sensors be fitted without disrupting guests?
Yes. AQUAIOT sensors are designed for retrofit in live environments, with no pipe cutting and no shutdown required. Our engineers handle the site survey, installation, and commissioning, often during the closed season.
How quickly can we produce records for an environmental health inspection?
Every reading and alert is held in tamper-evident logs with secure timestamps and is exportable on demand, so producing park-wide evidence for an environmental health officer, the HSE, or an insurer takes minutes rather than days of compiling scattered records.
Ready when you are

Stop leaving closed-season units uncovered.

Talk to our engineering team about continuous monitoring, shoulder-season cover, and audit-ready compliance records for your holiday park.

Holiday Park Legionella Monitoring – Speak to an AQUAIOT engineer about your estate.
Speak to an Expert
Shopping Cart (0 items)