Technology House, Stratfield Park, Waterlooville, PO7 7XN 023 9223 3611
Legionella Monitoring for GP Surgeries & Primary Care

Patient water safety,
monitored continuously.
Without an estates team.

Wireless temperature sensors at tanks, calorifiers, loops, sentinel taps, and treatment outlets, checking thresholds against HSE L8 and HTM 04-01 automatically, around the clock.

Live monitoring. Continuous compliance.
AQUAIOT L8 Dashboard
42Outlets OK
3Caution
1Alert
Tank A – Cold Feed18.4°COK
Outlet 7 – HWS Return49.1°CCaution
Outlet 12 – Sentinel56.8°CAlert
CW Tank B17.2°COK
No dedicated estates team on siteMost GP surgeries have no in-house estates or water-safety staff. L8 and HTM duties fall to a practice manager already running a busy primary care site, and manual rounds compete with everything else.
Vulnerable patients raise the stakesSurgeries see elderly, immunocompromised, and unwell patients every day, the group most exposed to waterborne infection. A temperature that drifts between visits puts the most fragile people at risk.
Treatment and dental outlets need close attentionMinor treatment rooms, dental chairs, and clinical handwash outlets carry specific water-safety expectations that a quick manual round rarely covers in full.
Branch surgeries stretch coverage thinPractices and networks running several branch sites cannot keep manual monitoring consistent across every location, and the record ends up with gaps.
The AQUAIOT Solution

Continuous visibility.
HTM-ready records.
No estates team needed.

AQUAIOT replaces manual rounds with continuous automated monitoring across your surgery and branch sites, so your L8 and HTM 04-01 record stays current without a dedicated estates team and is always ready for inspection.

Real-time temperature profiling at tanks, calorifiers, loops, sentinel outlets, and treatment outlets, continuous rather than periodic.
Threshold alerts against HSE L8 and HTM 04-01, immediate SMS, email, and app notification when temperatures drift into risk zones or a flush is missed.
Tamper-evident, exportable audit trails, instant evidence for CQC, the HSE, and your written scheme of control.
Request a Consultation
Live Outlet Status
CW Tank – Return Temp16.8°C
HWS Flow – Calorifier60.4°C
HWS Return – Loop 349.3°C
Sentinel Outlet 1256.8°C
Alert triggered – Outlet 12
Temperature above L8 calorifier threshold. Notification sent 14:32.
How It Works

Three steps to continuous L8 compliance

Step 01

Monitor

AQUAIOT sensors are deployed at tanks, loops, calorifiers, and sentinel outlets. Temperature is profiled continuously, every reading timestamped and logged to the cloud over secure cellular or LoRaWAN telemetry.

Step 02

Alert

When temperatures drift outside HSE L8 thresholds, or when a scheduled flush is missed, AQUAIOT triggers an immediate alert via SMS, email, or app, with role-based escalation rules for your estates team.

Step 03

Record

Every reading, alert, and action is captured in tamper-evident audit logs. Records are exportable on demand and integrate with CAFM, BMS, and AIMS systems, so audit preparation is minutes, not days.

Capabilities

Everything your L8 programme needs

Purpose-built for estates, facilities, and compliance teams managing water systems across single or multiple sites.

Real-time temperature profiling

Continuous monitoring at tanks, calorifiers, loops, and sentinel outlets. Every reading timestamped and stored, never a gap in your record.

HSE L8 threshold alerting

Thresholds checked against HSE L8 and ACoP guidance. Alerts fired immediately when cold water exceeds 20C or hot water falls below 50C at point of use.

Missed-flush detection

AQUAIOT detects when scheduled flushing routines are not completed and generates an automatic alert, so no event is undocumented.

Tamper-evident audit trails

Every reading and action is logged with a secure, unalterable timestamp. Exportable records ready for audit, inspection, or HSE enquiry at any time.

API / BMS / CAFM integration

Open and interoperable. AQUAIOT connects to your existing SCADA, AIMS, CAFM, and BMS platforms via RS485/Modbus or REST API, no lock-in.

Retrofit-friendly deployment

Non-invasive sensors designed for live environments. No pipe cutting, no shutdown. AQUAIOT engineers handle site survey, installation, and commissioning.

Compliance & Standards

Aligned to the standards your auditors check.

HTM 04-01 Compatible HSE L8 & HSG274 Part 2 Immutable Timestamped Logs Exportable Evidence
Book a Demo

No commitment. Talk to our engineering team.

Who It’s For

Built for every kind of primary care setting

GP Practices

Compliance without estates staff.

A single GP practice carries L8 and HTM 04-01 duties without dedicated water-safety staff, so monitoring falls to a practice manager already stretched. Automation gives a small team a reliable record without adding rounds to the day.

  • Automated monitoring without adding to practice workload
  • Immediate alerts when outlet temperatures drift into risk zones
  • Audit-ready records ready for CQC and HSE at short notice
  • Retrofit-friendly install with no shutdown of the surgery
Primary Care Networks

Every site, one dashboard.

Primary care networks coordinate water-safety duty across several member practices and shared sites, where manual monitoring is inconsistent and hard to evidence centrally. Continuous monitoring standardises the record across the network.

  • Continuous monitoring across every member site from one dashboard
  • Standardised records and alerts across the whole network
  • Role-based access for network leads and individual practice managers
  • Audit-ready evidence for network governance and inspectors
Health Centres

Mixed services, full coverage.

Health centres host GP services alongside community clinics, treatment rooms, and visiting specialists in one larger building, with varied outlet use across the day. Continuous monitoring gives a complete picture of a busier mixed site.

  • Continuous profiling across consulting, treatment, and clinical outlets
  • Alerts when low-use rooms or seasonal clinics develop risk
  • Tamper-evident records for the responsible person and inspectors
  • BMS and CAFM integration where the centre has building systems
Community & Branch Clinics

Dispersed sites, consistent records.

Branch surgeries and community clinics are spread across a wider area, making consistent manual L8 and HTM monitoring operationally fragile and expensive to deliver by hand. Continuous monitoring keeps every site covered.

  • Single dashboard view across every branch and clinic
  • Continuous monitoring without travelling to each location
  • Cellular and LoRaWAN telemetry for sites with limited infrastructure
  • Exportable evidence for each location on demand
Open, interoperable systems. No lock-in. Engineered for operational environments.
Cellular + LoRaWAN telemetry Encrypted payloads & OTA updates RS485/Modbus + REST API Role-based cloud dashboards CAFM / BMS compatible
Questions & Answers

Legionella monitoring for GP surgeries, answered

How does automated monitoring support HSE L8 and HTM 04-01 in a GP surgery?
AQUAIOT records temperatures continuously at tanks, calorifiers, loops, sentinel outlets, and treatment outlets and checks them against HSE L8 and HTM 04-01 guidance. It strengthens the duty holder’s written scheme of control with a complete, tamper-evident record, while responsibility for the overall control scheme remains with the practice.
Can it work without a dedicated estates or water-safety team?
Yes. AQUAIOT is designed for sites with no in-house estates staff. Continuous monitoring runs automatically, alerts go straight to the practice manager or responsible person, and our engineers handle the survey, install, and commissioning.
Does it cover treatment rooms and dental outlets?
Yes. Coverage includes tanks, calorifiers, hot and cold loops, sentinel outlets, and clinical or treatment outlets such as minor treatment rooms and dental handwash points, with closer profiling where outlets carry higher expectations.
Can it cover several branch surgeries from one place?
Yes. Continuous monitoring across every branch and clinic is visible from a single dashboard, with role-based access for practice and network managers, so coverage stays consistent without travelling to each site.
Can sensors be fitted without disrupting patient appointments?
Yes. AQUAIOT sensors are designed for retrofit in live environments, with no pipe cutting and no shutdown required. Our engineers handle the site survey, installation, and commissioning around clinic hours.
How quickly can we produce records for a CQC or HSE inspection?
Every reading and alert is held in tamper-evident logs with secure timestamps and is exportable on demand, so producing evidence for a CQC or HSE inspection takes minutes rather than days of compiling paper logbooks.
Ready when you are

Stop fitting L8 rounds into an already full clinic day.

Talk to our engineering team about continuous monitoring, automated alerts, and HTM-ready compliance records for your surgery or network.

GP Surgery Legionella Monitoring – Speak to an AQUAIOT engineer about your estate.
Speak to an Expert
Shopping Cart (0 items)