Process and welfare water,
monitored continuously.
Across the whole site.
Wireless temperature sensors at tanks, loops, sentinel taps, welfare outlets, and cooling systems, checking thresholds against HSE L8 and HSG274 automatically, around the clock.
Continuous visibility.
Site-wide records.
Audit-ready evidence.
AQUAIOT replaces labour-intensive manual rounds with continuous automated monitoring across process, welfare, and plant areas, so your L8 record stays current and is always ready for a BRC, customer, or HSE audit.
Temperature above L8 calorifier threshold. Notification sent 14:32.
Three steps to continuous L8 compliance
Monitor
AQUAIOT sensors are deployed at tanks, loops, calorifiers, and sentinel outlets. Temperature is profiled continuously, every reading timestamped and logged to the cloud over secure cellular or LoRaWAN telemetry.
Alert
When temperatures drift outside HSE L8 thresholds, or when a scheduled flush is missed, AQUAIOT triggers an immediate alert via SMS, email, or app, with role-based escalation rules for your estates team.
Record
Every reading, alert, and action is captured in tamper-evident audit logs. Records are exportable on demand and integrate with CAFM, BMS, and AIMS systems, so audit preparation is minutes, not days.
Everything your L8 programme needs
Purpose-built for estates, facilities, and compliance teams managing water systems across single or multiple sites.
Real-time temperature profiling
Continuous monitoring at tanks, calorifiers, loops, and sentinel outlets. Every reading timestamped and stored, never a gap in your record.
HSE L8 threshold alerting
Thresholds checked against HSE L8 and ACoP guidance. Alerts fired immediately when cold water exceeds 20C or hot water falls below 50C at point of use.
Missed-flush detection
AQUAIOT detects when scheduled flushing routines are not completed and generates an automatic alert, so no event is undocumented.
Tamper-evident audit trails
Every reading and action is logged with a secure, unalterable timestamp. Exportable records ready for audit, inspection, or HSE enquiry at any time.
API / BMS / CAFM integration
Open and interoperable. AQUAIOT connects to your existing SCADA, AIMS, CAFM, and BMS platforms via RS485/Modbus or REST API, no lock-in.
Retrofit-friendly deployment
Non-invasive sensors designed for live environments. No pipe cutting, no shutdown. AQUAIOT engineers handle site survey, installation, and commissioning.
Aligned to the standards your auditors check.
No commitment. Talk to our engineering team.
Built for every part of the manufacturing site
Process and welfare, fully covered.
Food processing sites combine process water, washdown systems, and large welfare facilities under constant audit pressure. Manual monitoring across the whole footprint is slow and leaves gaps in the record.
- Continuous monitoring across process, welfare, and plant from one dashboard
- Real-time profiling at sentinel outlets, loops, and welfare areas
- Threshold alerts checked against HSE L8 and HSG274 guidance
- SCADA and CAFM integration for engineering and quality teams
Water-intensive sites, watched closely.
Beverage production runs water-intensive operations alongside extensive welfare and plant systems, where temperature drift carries both safety and operational consequences. Continuous monitoring gives a precise, documented record.
- Dense profiling across welfare, plant, and associated outlets
- Immediate alerts when temperatures drift outside guidance
- Tamper-evident records for quality, safety, and audit teams
- Retrofit-friendly install with no shutdown of production
Welfare safety on dispersed sites.
Cold storage and logistics sites run large welfare facilities for shift workforces across dispersed buildings, where little-used outlets and quiet areas create stagnation risk that manual rounds miss.
- Continuous profiling across welfare and washroom outlets
- Automatic alerts when low-use outlets develop risk conditions
- Cellular and LoRaWAN telemetry across dispersed buildings
- Exportable evidence for each site on demand
Less time on rounds, more on uptime.
Site engineering teams carry L8 and HSG274 obligations alongside keeping production running. Automation frees skilled people from clipboard rounds and gives a defensible, always-current record across the whole site.
- Replace labour-intensive manual rounds with automated monitoring
- Reduce reactive call-outs by detecting drift before it escalates
- Tamper-evident records for BRC, customer, and HSE audits
- Open RS485/Modbus and REST API integration with site systems
Legionella monitoring for food and drink manufacturing, answered
How does automated monitoring support HSE L8 and HSG274 on a manufacturing site?
Can it cover welfare facilities and process areas together?
Does it help with cooling systems under HSG274?
How does it support BRC and customer audits?
Can sensors be fitted without stopping production?
Does it integrate with our SCADA and CAFM systems?
Related AQUAIOT monitoring solutions
Stop managing site-wide water safety by hand.
Talk to our engineering team about continuous monitoring, automated alerts, and audit-ready compliance records for your manufacturing site.

