Flow, metering and water loss

How is flow measured in an open channel?

Short answer

In an open channel the water does not fill the pipe, so flow has to be derived rather than measured directly. Either you measure depth alone and convert it through a structure with a known relationship between level and flow, such as a flume or a weir, or you measure depth and velocity together and multiply the wetted area by the velocity.

  • A full-pipe meter will not work. Ultrasonic and electromagnetic meters assume a full cross section and a known area.
  • Level alone is enough with a primary device. A flume or weir turns a single depth reading into a flow figure through its rating equation.
  • No structure means area-velocity. Depth gives the wetted area, a velocity sensor gives the speed, and the two are multiplied.
  • Silt is the usual reason it drifts. The level reading stays honest. The cross section you multiply it by quietly stops matching reality.

Why an open channel is a different problem

A meter on a pressurised pipe has an easy job, because the cross sectional area is fixed and known. Measure velocity, multiply by area, and you have flow. That is what a clamp-on ultrasonic meter does, and it is why a full pipe is one of its installation conditions.

An open channel breaks that assumption. A sewer running part full, a culvert, a storm channel or a stream has an area that changes every time the depth changes, and a velocity profile that changes with it. Nothing can be measured once and assumed. Both halves of the calculation have to be established continuously, or replaced with a structure that does the job for you.

The level-only method: flumes and weirs

The oldest and still the most accurate approach is to build a constriction with known hydraulics into the channel. A flume or a weir forces the water into a predictable relationship between upstream depth and flow, so a single level measurement is enough. Measure the head upstream of the structure with a radar or ultrasonic level sensor, apply the rating equation for that structure, and read off flow.

This is cheap to instrument and hard to beat on accuracy, but it depends entirely on the structure. The flume must be built to specification, set truly level, undamaged, free of debris, and operating within its designed range. The approach conditions upstream matter as much as the sensor does, because a disturbed or asymmetric approach invalidates the rating just as surely as a cracked crest.

The failure mode to watch is drowning. If downstream levels rise enough to submerge the structure, it stops behaving according to its rating and the flow figure becomes meaningless at exactly the moment during a storm when somebody wants to trust it.

The area-velocity method

Where there is no structure, and building one is not practical, flow is calculated from first principles. Depth is measured and converted to a wetted area using the channel’s known geometry. Velocity is measured separately. The two are multiplied.

Velocity is obtained either from a sensor in the flow, typically Doppler, or from a non-contact sensor above it that reads the speed of the surface using microwave or radar. Surface velocity is not the same as average velocity, because the water moves faster at the surface than at the bed and walls, so a surface reading is converted using a coefficient that depends on the channel and the depth.

Non-contact measurement is specified more often than its accuracy alone would justify, and the reason is access rather than metrology. A sensor mounted above the flow does not foul, does not need cleaning in a confined space, and does not require somebody to enter a chamber to service it. In a sewer or a wet well that consideration outweighs a great deal.

What actually goes wrong

Silt is the most common cause of a number that slowly stops being true. The depth reading remains perfectly accurate, but the cross section assumed at commissioning is no longer the cross section that exists, so the area the depth is converted into is wrong. Because it degrades gradually, nothing alarms and the error is invisible until someone surveys the channel. The same applies to debris, fat deposits and any change to the invert.

Backwater and surcharge break the level-only method outright, as above, and distort area-velocity readings too, because during surcharge the flow may reverse or stall while the depth stays high. A tide-locked outfall produces exactly this behaviour on a predictable cycle.

Sensor choice matters at the surface. An ultrasonic level sensor measures time of flight through air and is affected by foam, steam and heavy condensation, all of which are normal in a sewer. Radar copes considerably better with those conditions, which is why it tends to be specified for wastewater rather than clean water applications.

Finally, access governs verification. If the plan assumes somebody will periodically enter to check the channel, in a sewer or wet well that is a confined space entry with its own permit regime, its own gas testing and its own cost. That cost belongs in the comparison at the design stage rather than being discovered later.

Choosing between them

If a flume or weir already exists and is in good condition, use it and instrument the level. It is the cheapest accurate answer available.

If there is no structure, the channel geometry varies, or surcharge is likely, use area-velocity, and prefer non-contact sensing wherever the location is confined or hazardous.

If the figure is going into a regulatory return rather than into operational decisions, check first whether MCERTS certification applies to the application, because that constrains the equipment and the installation before any other consideration does.

What AQUAIOT uses for this

The solutions and hardware that apply to the question above.